Correction: Signal Intensities Derived from Different NMR Probes and Parameters Contribute to Variations in Quantification of Metabolites
نویسندگان
چکیده
We discovered that serious issues could arise that may complicate interpretation of metabolomic data when identical samples are analyzed at more than one NMR facility, or using slightly different NMR parameters on the same instrument. This is important because cross-center validation metabolomics studies are essential for the reliable application of metabolomics to clinical biomarker discovery. To test the reproducibility of quantified metabolite data at multiple sites, technical replicates of urine samples were assayed by 1D-(1)H-NMR at the University of Alberta and the University of Michigan. Urine samples were obtained from healthy controls under a standard operating procedure for collection and processing. Subsequent analysis using standard statistical techniques revealed that quantitative data across sites can be achieved, but also that previously unrecognized NMR parameter differences can dramatically and widely perturb results. We present here a confirmed validation of NMR analysis at two sites, and report the range and magnitude that common NMR parameters involved in solvent suppression can have on quantitated metabolomics data. Specifically, saturation power levels greatly influenced peak height intensities in a frequency-dependent manner for a number of metabolites, which markedly impacted the quantification of metabolites. We also investigated other NMR parameters to determine their effects on further quantitative accuracy and precision. Collectively, these findings highlight the importance of and need for consistent use of NMR parameter settings within and across centers in order to generate reliable, reproducible quantified NMR metabolomics data.
منابع مشابه
Estimation of harmonic interference parameters of surface-NMR signal using an adaptive method and residual signal power
Surface nuclear magnetic resonance (surface-NMR) method is a well-known tool for determining the water-bearing layers and subsurface resistivity structure. Harmonic interference is an inevitable interference in surface-NMR measurements. Accurate estimation of harmonic interference parameters (i.e., fundamental frequency, phase and amplitude) leads to better retrieval of power-line harmonics and...
متن کاملCorrection to Simultaneous Quantification and Identification of Individual Chemicals in Metabolite Mixtures by Two-Dimensional Extrapolated Time-Zero 1H–13C HSQC (HSQC0)
Quantitative one-dimensional (1D) (1)H NMR spectroscopy is a useful tool for determining metabolite concentrations because of the direct proportionality of signal intensity to the quantity of analyte. However, severe signal overlap in 1D (1)H NMR spectra of complex metabolite mixtures hinders accurate quantification. Extension of 1D (1)H to 2D (1)H-(13)C HSQC leads to the dispersion of peaks al...
متن کاملDistribution-based classification method for baseline correction of metabolomic 1D proton nuclear magnetic resonance spectra.
Baseline distortion in 1D (1)H NMR data complicates the quantification of individual components of biofluids in metabolomic experiments. Current 1D (1)H NMR baseline correction methods usually require manual parameter and filter tuning by experienced users to obtain desirable results from complex metabolomic spectra, thus becoming prone to correction variation and biased quantification. We pres...
متن کاملروشی نوین در کاهش نوفه رایسین از مقدار بزرگی سیگنال دیفیوژن در تصویربرداری تشدید مغناطیسی (MRI)
The true MR signal intensity extracted from noisy MR magnitude images is biased with the Rician noise caused by noise rectification in the magnitude calculation for low intensity pixels. This noise is more problematic when a quantitative analysis is performed based on the magnitude images with low SNR(<3.0). In such cases, the received signal for both the real and imaginary components will fluc...
متن کاملSimultaneous Spectrophotometric Determination of Heavy Metal Ions Using Several Chemometrics Methods: Effect of Different Parameters of Savitzky-Golay and Direct Orthogonal Signal Correction Filters
Direct orthogonal signal correction(DOSC) and Savitzky-Golay filters (SGF) were applied as preprocessing methods on the original and first derivative absorbance data. Principle component regression (PCR), partial least squares (PLS) and iterative target transformation factor analysis (ITTFA), were used in spectrophotometric simultaneous determination of heavy divalent metal ions, l...
متن کامل