Fracture severity of distal radius fractures treated with locking plating correlates with limitations in ulnar abduction and inferior health-related quality of life

نویسندگان

  • Serafim Tsitsilonis
  • David Machó
  • Sebastian Manegold
  • Björn Dirk Krapohl
  • Florian Wichlas
چکیده

INTRODUCTION/BACKGROUND The operative treatment of distal radius fractures has significantly increased after the introduction of locking plates. The aim of the present study was the evaluation of health-related quality of life, functional and radiological outcome of patients with distal radius fractures treated with the locking compression plate (LCP). MATERIALS AND METHODS In the present study 128 patients (130 fractures) that were operatively treated with the LCP (2.4 mm/3.5 mm, Synthes(®)) were retrospectively evaluated. Mean follow-up was 22.7 months (SD 10.6). The fractures were radiographically evaluated (radial inclination, palmar tilt, ulnar variance) pre-, postoperatively and at the last follow-up visit. Range of motion (ROM) was documented. Grip strength was assessed with the use of a JAMAR dynamometer. The score for disabilities of the arm, shoulder and hand (DASH) and the Gartland-Werley score (GWS) were evaluated. Health-associated quality of life was assessed with use of SF-36 Health Survey. RESULTS Postoperative reduction was excellent; at the last follow-up visit only minimal reduction loss was observed. Except for pronation, a statistically significant decrease of ROM was present; in most cases that was not disturbing for the patients. The injured side achieved 83.9% of grip strength of the intact side. Mean DASH was 18.9 and mean GWS was 3.5. Health-associated quality of life was generally not compromised. However, limitations in ulnar abduction correlated with inferior quality of life. Fracture severity correlated with inferior quality of life, despite the absence of correlation with the functional and radiological outcome. Complication rate was low. CONCLUSIONS Fracture severity seems to affect ulnar abduction and therefore patient quality of life, despite almost anatomical reduction; the objective and subjective scores were in most cases excellent. Modern everyday activities, such as keyboard typing, could be associated with the present results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

Complications and Plate Removal Surgeries after Performing Volar Plating of Unstable Distal Radius Fractures

Complications have often been reported in the literature after distal radius fractures treated conservatively or operatively [1-3]. Previously, the main indication for volar plating was a volar Barton or Smith fracture, but now volar locking plates are the most commonly used treatment for unstable distal radius fractures and during the last decade this method has become increasingly popular [4]...

متن کامل

The Role of Biplanar Distal Locking in Intramedullary Nailing of Tibial Shaft Fractures

Background: To compare the union times of the uncomplicated tibial shaft fractures, which were distally locked by twocoronal and one sagittal screws and by only two coronal screws.Methods: 45 patients with tibial shaft treated with intramedullary nailing included in this study. 23 of 45 fractureswere treated with uniplanar two distal interlocking (Group 1) and 22 fractures were treated with bip...

متن کامل

Functional Results of Unstable (Type 2) Distal Clavicle Fractures Treated with Superior Anterior Locking Plate

Background: The treatment of distal clavicle fracture is always a challenge, as it is mostly unstable and has higherrate of delayed union, malunion, non-union and associated acromioclavicular arthritis. So the management of thesefractures remains controversial. The purpose of this study is to evaluate the functional results of Type 2 distal endclavicle fractures treated with superior anterior l...

متن کامل

Assessment of the treatment outcome of closed extra-articular distal tibia fracture: IM nailing vs plating

  Abstract   Background: The tibial diaphyseal fractures are the most common type of long   bone fractures encountered by most orthopedic surgeons. In accordance with descriptive indices of tibia fractures on the basis of their location in the bone, distal tibia   fractures have the second incidence of all tibia fractures after the middle tibia fractures.   The purpose of the study was to asses...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016