BACKGROUND Ion beam therapy represents a promising approach to treat prostate cancer, mainly due to its high conformity and radiobiological effectiveness. However, the presence of prostate motion, patient positioning and range uncertainties may deteriorate target dose and increase exposure of organs at risk. Spacer gel injected between prostate and rectum may increase the safety of prostate cancer (PC) radiation therapy by separating the rectum from the target dose field. The dosimetric impact of the application of spacer gel for scanned carbon ion therapy of PC has been analyzed at Heidelberg Ion-Beam Therapy Center (HIT). MATERIALS AND METHODS The robustness of ion therapy treatment plans was investigated by comparison of two data sets of patients treated with and without spacer gel. A research treatment planning system for ion therapy was used for treatment plan optimization and calculation of daily dose distributions on 2 to 9 Computed Tomography (CT) studies available for each of the 19 patients. Planning and daily dose distributions were analyzed with respect to target coverage, maximal dose to the rectum (excluding 1 ml of the greatest dose; Dmax-1 ml) and the rectal volume receiving dose greater than 90% of prescribed target dose (V90Rectum), respectively. RESULTS The application of spacer gel did substantially diminish rectum dose. Dmax-1 ml on the treatment planning CT was on average reduced from 100.0 ± 1.0% to 90.2 ± 4.8%, when spacer gel was applied. The robustness analysis performed with daily CT studies demonstrated for all analyzed patient cases that application of spacer gel results in a decrease of the daily V90Rectum index, which calculated over all patient cases and CT studies was 10.2 ± 10.4 [ml] and 1.1 ± 2.1 [ml] for patients without and with spacer gel, respectively. CONCLUSIONS The dosimetric benefit of increasing the distance between prostate and rectum using spacer gel for PC treatment with carbon ion beams has been quantified. Application of spacer gel substantially reduced rectal exposure to high treatment dose and, therefore, can reduce the hazard of rectal toxicity in ion beam therapy of PC. The results of this study enable modifications of the PC ion therapy protocol such as dose escalation or hypofractionation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of prostate cancer radiotherapy using of a spacer gel, volumetric modulated arc therapy and a single biological organ at risk objective

Background: The aim was to evaluate the benefit of technical advances for treatment planning: introduction of a hydrogel spacer, VMAT (volumetric modulated arc therapy) and a single biological organ at risk objective for the rectum and bladder. Initial standard was a step-and-shoot IMRT (intensity modulated radiotherapy) without a spacer and conventional organ at risk objectives.  Material...

متن کامل

Preclinical investigations towards the first spacer gel application in prostate cancer treatment during particle therapy at HIT

BACKGROUND The application of spacer gel represents a promising approach to reliably spare the rectal frontal wall during particle therapy (IJROBP 76:1251-1258, 2010). In order to qualify the spacer gel for the clinical use in particle therapy, a variety of measurements were performed in order to ensure the biological compatibility of the gel, its physical stability during and after the irradia...

متن کامل

Application of a spacer gel to optimize three-dimensional conformal and intensity modulated radiotherapy for prostate cancer.

BACKGROUND AND PURPOSE The aim was to evaluate the impact of a spacer gel on the dose distribution, applying three-dimensional conformal (3D CRT) and intensity modulated radiotherapy (IMRT) planning techniques. MATERIAL AND METHODS The injection of a spacer gel (10 ml SpaceOAR™) was performed between the prostate and rectum under transrectal ultrasound guidance in 18 patients with prostate ca...

متن کامل

The effect of Rectal Retractor, a rectal protector on rectal dose in radical prostate radiotherapy

Introduction: The close proximity of the rectum tissue to the prostate gland results in rectal toxicity during prostate radiotherapy. Rectal Retractor (RR) is a rectal displacement technique that inserts into the rectum, as a result, the lateral and dorsal part of the rectal wall push away from high dose areas. The aim of this study was to investigate the dosimetric consequence...

متن کامل

Rectal dose to prostate cancer patients treated with proton therapy with or without rectal spacer

The purpose of this study was to evaluate whether a spacer inserted in the prerectal space could reduce modeled rectal dose and toxicity rates for patients with prostate cancer treated in silico with pencil beam scanning (PBS) proton therapy. A total of 20 patients were included in this study who received photon therapy (12 with rectal spacer (DuraSeal™ gel) and 8 without). Two PBS treatment pl...

متن کامل