Measurement of Ramp Rate Sensitivity in Model Dipoles With Ebanol-Coated Cable
نویسندگان
چکیده
Ramp rate sensitivity in superconducting dipole magnets has been shown to vary in an unpredictable fashion between magnets constructed using similar fabrication techniques. Test results from a series of model magnets are presented, one of which was constructed using ebanolcoated strands. The ramp rate sensitivity and ac loss observed is described.
منابع مشابه
Evaluation of Methods for Computing Free-Flow Speed and Its Significance in the HCM 2010; Case Study: A Ramp-Weaving Segment
The core methodology of the Highway Capacity Manual (HCM) 2010 for freeway analyses is based on Free-Flow Speed (FFS). Moreover, weaving segments are major elements of freeway facilities that form where two one-way traffic streams intersect by merging and diverging maneuvers. Hence, this study used three different methods to compute FFS of a ramp-weaving segment, and then employed the proposed ...
متن کاملElimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry
A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...
متن کاملStability Analysis and Robust PID Control of Cable Driven Robots Considering Elasticity in Cables
In this paper robust PID control of fully-constrained cable driven parallel manipulators with elastic cables is studied in detail. In dynamic analysis, it is assumed that the dominant dynamics of cable can be approximated by linear axial spring. To develop the idea of control for cable robots with elastic cables, a robust PID control for cable driven robots with ideal rigid cables is firstly de...
متن کاملNonlinear Cable equation, Fractional differential equation, Radial point interpolation method, Meshless local Petrov – Galerkin, Stability analysis
The cable equation is one the most fundamental mathematical models in the neuroscience, which describes the electro-diffusion of ions in denderits. New findings indicate that the standard cable equation is inadequate for describing the process of electro-diffusion of ions. So, recently, the cable model has been modified based on the theory of fractional calculus. In this paper, the two dimensio...
متن کاملThe Effect of HLB on the Release Profile of Atenolol from Ethyl Cellulose-coated Tablets
It is possible to alter the permeability of ethyl cellulose membrane with certain materials such as surfactants. In this study the effect of surfactant concentration and different HLB values on the release rate of atenolol from ethyl cellulose-coated tablets was evaluated. The results showed that when the concentration of surfactant increased, the rate of drug release also increased. The kineti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1995