Comparison of Latencies and Time to Stabilization of Pulse Oximeters at a Tertiary Health Care Facility
نویسندگان
چکیده
Introduction: Fingertip pulse oximeters are commonly used as non-invasive modes of measuring oxygen saturation (SpO2) and heart rate (HR) in critical care units. In these cases, a shorter duration of time required obtaining the measurement and time to stabilization is crucial. Objective: Our aim was to compare two new generation pulse oximeters with respect to latency in the fi rst reading and time to stabilization of SpO2 and HR. Materials and Methods: This study was a prospective, comparative non-blinded, observational study of two fi ngertip pulse oximeters (Nonin Medical 9560 and CHOICEMMED MD300C1) in 20 in patients at Benedectine Health Center suffering from either one or more chronic diseases. SpO2 and HR readings were collected at the time of fi rst display, 30 s, 60 s and at the time of stabilization of the reading (no more than a 1% change in SpO2, <3 bpm change in HR). Statistical analysis was performed with SAS 9.2 software. Results: A total of 20 subjects were monitored. The average time to fi rst reading across all fi ngers was signifi cantly longer with the CHOICEMMED device (10.3 ± 0.8 s) as compared to Nonin Medical (9.0 ± 0.8 s) pulse oximeter. The mean difference was 1.3 s (95% confi dence interval (CI), (0.05, 2.61), P = 0.04). The average time to stabilization of SpO2 across all fi ngers was also statistically signifi cantly longer in the CHOICEMMED (27.4 ± 2.2 s) than Nonin Medical pulse oximeter (11.4 ± 2.0 s). The mean difference was 15.9 s (95% CI (12.57. 19.29), P < 0.0001). Conclusion: The pulse oximeter (Model 9560) by Nonin Medical showed shorter latency for fi rst reading and time to stabilization when compared to CHOICEMMED (MD300C1), which is a distinct advantage in emergency situations in acute patients. Further larger studies are needed to validate these fi ndings in different clinical settings.
منابع مشابه
Does pulse oximeter use impact health outcomes? A systematic review
OBJECTIVE Do newborns, children and adolescents up to 19 years have lower mortality rates, lower morbidity and shorter length of stay in health facilities where pulse oximeters are used to inform diagnosis and treatment (excluding surgical care) compared with health facilities where pulse oximeters are not used? DESIGN Studies were obtained for this systematic literature review by systematica...
متن کاملAn Evaluation of the Role of an Intermediate Care Facility in the Continuum of Care in Western Cape, South Africa
Background A comprehensive primary healthcare (PHC) approach requires clear referral and continuity of care pathways. South Africa is a lower-middle income country (LMIC) that lacks data on the role of intermediate care (IC) services in the health system. This study described the model of service provision at one facility in Cape Town, including reason for admission, the mix of services and ski...
متن کاملMINIMUM TIME SWING UP AND STABILIZATION OF ROTARY INVERTED PENDULUM USING PULSE STEP CONTROL
This paper proposes an approach for the minimum time swing upof a rotary inverted pendulum. Our rotary inverted pendulum is supported bya pivot arm. The pivot arm rotates in a horizontal plane by means of a servomotor. The opposite end of the arm is instrumented with a joint whose axisis along the radial direction of the motor. A pendulum is suspended at thejoint. The task is to design a contro...
متن کاملThe Economic Standpoint of Referral System at Using Tertiary Hospital Services in Iran
Background and purpose: Although, economically, referral systems make utilization of health facilities at different levels sound, in many countries caretakers often bypass primary care facilities that are regularly costlier for caretakers and health care systems. The main objective of the current study was to assess the utilization of hospital services with more emphasis on economic point of vi...
متن کاملEmergency Referral Transport for Maternal Complication: Lessons from the Community Based Maternal Death Audits in Unnao District, Uttar Pradesh, India
Background An effective emergency referral transport system is the link between the home of the pregnant woman and a health facility providing basic or comprehensive emergency obstetric care. This study attempts to explore the role of emergency transport associated with maternal deaths in Unnao district, Uttar Pradesh (UP). Methods A descriptive study was carried out to assess the causes of a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -