Rapid method for determination of 90Sr in seawater by liquid scintillation counting with an extractive scintillator.

نویسندگان

  • Masaki Uesugi
  • Ryosuke Watanabe
  • Hiroaki Sakai
  • Akihiko Yokoyama
چکیده

A rapid determination method of 90Sr is developed for the monitoring of seawater around the Fukushima Daiichi Nuclear Power Plant (FDNPP). Three ideas of chemical separation and measurements to accelerate 90Sr analysis are investigated. Strontium is co-precipitated in a two-step procedure with hydroxyapatite after the removal of magnesium phosphate in the presence of citric acid. The purification process of strontium is in combination with solid phase extraction disks. One or two sheets of Sr Rad disk and cyclic operations are examined to eliminate interfering substances and secure the exchange capacity. The suitable conditions of adsorption and stripping are determined with a 85Sr tracer. Seawater samples up to 1L can be analyzed within 4h. Additionally, the appropriate pH conditions to extract strontium to the scintillator are studied, and the 90Sr activity is assessed via liquid scintillation counting using an extractive scintillator based on the di-(2-etyl hexyl)-phosphoric acid (HDEHP) extraction method. The new scintillation counting method involves a small quenching effect and a low background compared to the conventional emulsion scintillator method. The minimum detectable activity (MDA) is 35mBq/L of 90Sr in 180min of counting. The proposed method provides analytical results within a day after receipt of the samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurements of Strontium-90 in portuguese milk samples using liquid scintillation counting technique

The objective of this study is the implementation of a method combining extraction chromatography and liquid scintillation counting (LSC) technique to the determination of 90Sr in milk samples. The strontium separation is performed using the commercially available Sr-resin (Eichrom) and the beta counting is carried out using a liquid scintillation detector system (Tri-Carb 3170 TR/SL, Packard)....

متن کامل

Measurement of 90sr in aqueous samples using liquid scintillation counting with full spectrum DPM method.

90Sr activity was measured with the full spectrum DPM (FS-DPM) counting method after plotting the quench correction curves of 90Sr and 90Y, and the FS-DPM method was applied to determine the 90Sr in liquid waste samples. The optimum regions of 90Sr and 90Y were set for measuring 90Sr with the dual label DPM (DL-DPM) method. The direct measurement of purified 90Sr with spectrum unfolding techniq...

متن کامل

Simultaneous measurement of 89Sr and 90Sr in aqueous samples by liquid scintillation counting using the spectrum unfolding method.

Two radiostrontium isotopes, 89Sr and 90Sr, were measured simultaneously by liquid scintillation counter coupling with a full spectrum DPM counting protocol. Strontium was separated from the aqueous media by extraction chromatography using Sr-spec resin. Individual count rates were evaluated from quench correlation curves for 89Sr and 90Sr related with SIS and tSIE quench indicators. The method...

متن کامل

Determination of chemical and radiochemical purity of [14C] clozapine by high performance liquid chromatography and liquid scintillation [Persian]

Introduction: The mechanism of action and metabolism of clozapine, a complex drug used in psychopharmacology, is not completely understood. The effects of this compound in human body are related to some interactions with serotonin and dopamine neurotransmitter receptors. To further elucidate the mechanism of action and to support ongoing drug metabolism studies, [14C] clozapine with suita...

متن کامل

The Effect of Quench on Quantitating Alpha Radionuclides by Liquid Scintillation Counting

Detecting and quantitating alpha emitting radionuclides are routine tasks in nuclear energy and environmental monitoring. For this purpose, liquid scintillation counting (LSC) is an excellent method because alphas are counted with nearly 100% counting efficiency with low backgrounds, even with severe quenching. Quenching agents such as inorganic acids, organic acids, and extractive scintillator...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 178  شماره 

صفحات  -

تاریخ انتشار 2018