Deep Sclerectomy With a New Nonabsorbable Uveoscleral Implant (Esnoper-Clip): 1-Year Outcomes

نویسندگان

  • Jordi Loscos-Arenas
  • Angels Parera-Arranz
  • Pau Romera-Romera
  • Jordi Castellvi-Manent
  • Antoni Sabala-Llopart
  • Julio de la Cámara-Hermoso
چکیده

PURPOSE To report the safety and the effectiveness of deep sclerectomy (DS) with a new nonabsorbable uveoscleral hema implant (Esnoper-Clip) designed to increase trabecular and uveoscleral outflow and to achieve higher intrascleral blebs. MATERIALS AND METHODS Twenty-seven eyes of 27 patients with open-angle glaucoma, who underwent DS with an Esnoper-Clip implant, were included in this study. All patients were followed up after 12 months. RESULTS A significant decrease in intraocular pressure was observed after surgery, changing from a preoperative mean of 26.6±5.2 mm Hg to a postoperative mean of 15.3±5 mm Hg (P<0.001) at 12 months. There was also a significant reduction in the number of glaucoma drugs needed, varying from 2.5 per patient to 0.3 (P<0.001) 1 year after surgery. The main intrascleral lake height and volume at 12 months was 0.7±0.1 mm and 3.9±1.3 mm, respectively. No intraoperative complications occurred. The main postoperative complications were a positive Seidel test result at 24 hours in 2 eyes (7.4%), hyphema in 2 eyes (7.4%), and choroidal detachment in 1 eye (3.7%). All these complications resolved successfully. The need for additional mitomycin-C injections was recorded in 4 eyes (14.8%), twice in 2 of them. Twelve eyes (44.4%) underwent postsurgical Nd:YAG laser goniopuncture with a mean time between surgery and this procedure of 4.3 months. Mean intraocular pressure after Nd:YAG laser goniopuncture decreased from 19.2 to 15.5 mm Hg (P<0.001). CONCLUSION DS with an uveoscleral hema implant (Esnoper-Clip) is a safe and effective technique for the management of open-angle glaucoma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anterior Segment Optical Coherence Tomography Imaging of Filtering Blebs after Deep Sclerectomy with Esnoper-Clip Implant: One-year Follow-up

PURPOSE To describe the technique of deep sclerectomy with the new Esnoper-Clip® implant, the clinical outcome and the anatomic characteristics of filtering blebs, using anterior segment optical coherence tomography (AS-OCT). METHODS A prospective case-series study was conducted in five eyes (5 patients) with open angle glaucoma. The fornix-based deep sclerectomy with Esnoper-Clip® implant wa...

متن کامل

A New Implant for Deep Sclerectomy: Esnoper®

Newer non-reabsorbing implants have been developed to maintain the hypotensor effect of nonpenetrating deep sclerectomy. In this article the authors discuss a new non-reabsorbing implant with 2-hydroxyethyl methacrylate (Esnoper®, AJL Ophthalmics, SA, Miñano, Alava, Spain), its design, technique of implantation and the available scientific evidence.

متن کامل

[Ultrasound biomicroscopy in deep sclerectomy with a new acrylic implant].

OBJECTIVE To describe the ultrasound biomicroscopic (UBM) characteristics seen in patients who have undergone deep phaco-sclerectomy with a new acrylic implant (Esnoper). SUBJECTS, MATERIAL AND METHODS UBM exploration was performed 12 months after deep phaco-sclerectomy in three patients with chronic open angle glaucoma. RESULTS One year after surgery, all three patients had intraocular pre...

متن کامل

Deep Sclerectomy with Nonabsorbable Implant (T-Flux) in Patients with Pseudoexfoliation Glaucoma

Purpose. To evaluate the effectiveness of deep sclerectomy with T-flux implant (DS T-flux) in patients with pseudoexfoliation glaucoma (PExG). Methods. 20 eyes of 18 patients with medically uncontrolled PExG have undergone DS T-flux implantation. Postoperatively we evaluated the IOP values and the frequency of complications. The minimum follow-up time was 12 months (20 eyes) and the maximum 24 ...

متن کامل

Ultrasound biomicroscopy and optical coherence tomography imaging of filtering blebs after deep sclerectomy with new collagen implant.

PURPOSE To identify the clinical and anatomic characteristics of filtering blebs after glaucoma surgery with a new biodegradable collagen implant, Ologen, using ultrasound biomicroscopy (UBM) and Visante anterior segment optical coherence tomography (OCT). METHODS The authors conducted a prospective interventional case series in 15 eyes with openangleglaucoma. The authors performed limbal-bas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 24  شماره 

صفحات  -

تاریخ انتشار 2015