Radiographic Assessment of the presigmoid retrolabyrinthine approach
نویسندگان
چکیده
BACKGROUND Lesions of the petroclival fissure are difficult to access surgically. Both retrosigmoid and presigmoid retrolabyrinthine approaches have been described to successfully treat these complex tumors. The retrosigmoid approach offers quick and familiar access, whereas the presigmoid retrolabyrinthine approach reduces the operative distance and the need for cerebellar retraction. The presigmoid retrolabyrinthine approach, however, is constrained by anatomical limits that can be subject to patient variation. We sought to characterize the surgically relevant variation to guide preoperative assessment. METHODS One hundred and seventy-seven high-resolution computed tomography scans of the head (without preexisting pathology) were reviewed. Three hundred and fifty-four temporal bone scans were analyzed for level of aeration, size of Trautmann's triangle dura, and petrous slope. Petrous slope is the angle between the anterior sigmoid sinus and the petroclival fissure at the level of the internal acoustic canal. RESULTS Trautmann's triangle area had a mean of 185.15 mm2 (range 71.4-426.7 mm2). Petrous slope had a mean value of 149° (range 106-178°). Increasing aeration was found to be correlated with decreasing petrous slope and decreasing Trautmann's triangle area. CONCLUSION The presigmoid retrolabyrinthine approach is uniquely confined. Variations in temporal bone anatomy can have dramatic impacts on the operative time, risk profile, and final exposure. Preoperative assessment is critical in guiding the surgeon on the appropriateness of approach. Preoperative measurement of Trautmann's triangle, petrous slope, and aeration can help to reduce surgical morbidity.
منابع مشابه
Anatomic Study of Endolymphatic Sac On Posterior Fossa dura for Meniere’s disease and for transpetrosal skull base approach
Purpose: Compromising the endolymphatic sac in the skull base approaches impose a high risk of progressive hearing loss. The authors topographically measured the relationship between endolymphatic sac (ES) and the surrounding anatomic structures in an effort finding the safety distance while incising the presigmoidal dura. Material and methods: Three imported formalin-fixed latex-injected cadav...
متن کاملSimulation-Based Neurosurgical Training for the Presigmoid Approach With a Physical Model.
BACKGROUND In recent years, there has been growing interest in the use of simulation to supplement conventional surgical training. Simulation remains, however, in its infancy in neurosurgery. OBJECTIVE To report on and assess the utility of a simulation physical model for the presigmoid approach. METHODS The Congress of Neurological Surgeons created a Simulation Committee to explore and dev...
متن کاملValidation of Goniometric Method in the Assessment of Lordosis by Radiographic Analysis
Background & Aims: Cervical spine is prone to various abnormalities and sport injuries. There is still no non-aggressive measurement instrument with high reliability for easy and rapid assessment of cervical spine secondary complications. The aim of this research was to investigate the validity of goniometric method for cervical lordosis measurement through radiography. Method: In this study, 1...
متن کاملEvolution of the posterior petrosal approach.
In this article, the authors review the history of the posterior petrosal approach. The early foundation of the retrolabyrinthine lateral petrosectomy has its roots in the otolaryngology literature. These early approaches were limited in exposure by the tentorium superiorly and the sigmoid sinus posteriorly. Although the concept of a transtentorial approach was originally combined with a comple...
متن کاملQuality Control Assessment of Radiology Devices in Kerman Province, Iran
Introduction Application of quality control (QC) programs at diagnostic radiology departments is of great significance for optimization of image quality and reduction of patient dose. The main objective of this study was to perform QC tests on stationary radiographic X-ray machines, installed in 14 hospitals of Kerman province, Iran. Materials and Methods In this cross-sectional study, QC tests...
متن کامل