Performance of POC-CCA® in diagnosis of schistosomiasis mansoni in individuals with low parasite burden.
نویسندگان
چکیده
INTRODUCTION Schistosomiasis, caused by Schistosoma mansoni, is a public health concern in Brazil. However, the most popular diagnostic method, the Kato-Katz technique, exhibits low sensitivity in low-endemicity areas. We aimed to compare the performance of an immunological assay, the point-of-care circulating cathodic antigen (POC-CCA®) test, with that of two parasitological techniques in a low-endemicity population. METHODS Our study included 141 individuals living in Estreito de Miralta, Minas Gerais, Brazil. Fecal samples were obtained from all participants and analyzed for schistosomiasis using two parasitological techniques: the Kato-Katz technique and the saline gradient technique. Additionally, POC-CCA® strips were utilized for testing urine samples. The results obtained by the different techniques were compared. RESULTS Analysis of two or 24 slides using the Kato-Katz technique resulted in a positivity rate of 10.6% (15/141) or 19.1% (27/141), respectively. The saline gradient technique yielded a positivity rate of 17.0% (24/141). The prevalence according to both parasitological techniques was 24.1% (34/141). The POC-CCA® test yielded a positivity rate of 22.7% (32/141); however, the positivity rate was merely 2.1% if trace results were considered negative. The agreements observed between POC-CCA® and the parasitological techniques were good (Kappa indexes > 0.64). The POC-CCA® test was more sensitive than the two-slide Kato-Katz technique (p < 0.05) in detecting cases of S. mansoni infection when trace results were considered positive. CONCLUSIONS These findings reinforce the importance of using multiple diagnostic techniques in low-endemicity areas for effective control of disease.
منابع مشابه
Improvement of POC-CCA Interpretation by Using Lyophilization of Urine from Patients with Schistosoma mansoni Low Worm Burden: Towards an Elimination of Doubts about the Concept of Trace
BACKGROUND Accurate diagnostic techniques for schistosomiasis are essential for prevalence determination and identification of positive patients. A point-of-care test for detecting schistosome circulating cathodic antigen (POC-CCA) has been evaluated for its accuracy in different endemic regions. This reagent strip/dipstick based assay has showed high sensitivity for individuals with high or mo...
متن کاملEvaluation of diagnostic methods for the detection of intestinal schistosomiasis in endemic areas with low parasite loads: Saline gradient, Helmintex, Kato-Katz and rapid urine test
BACKGROUND In some tropical countries, such as Brazil, schistosomiasis control programs have led to a significant reduction in the prevalence and parasite burden of endemic populations. In this setting, the Kato-Katz technique, as the standard diagnostic method for the diagnosis of Schistosoma mansoni infections, which involves the analysis of two slides from one fecal sample, loses its sensiti...
متن کاملAccuracy of Urine Circulating Cathodic Antigen Test for the Diagnosis of Schistosoma mansoni in Preschool-Aged Children before and after Treatment
BACKGROUND The Kato-Katz technique is widely used for the diagnosis of Schistosoma mansoni, but shows low sensitivity in light-intensity infections. We assessed the accuracy of a commercially available point-of-care circulating cathodic antigen (POC-CCA) cassette test for the diagnosis of S. mansoni in preschool-aged children before and after praziquantel administration. METHODOLOGY A 3-week ...
متن کاملSensitivity and specificity of the circulating cathodic antigen rapid urine test in the diagnosis of Schistosomiasis mansoni infection and evaluation of morbidity in a low- endemic area in Brazil.
INTRODUCTION: The Kato-Katz technique is the standard diagnostic test for Schistosoma mansoni infection in rural areas. However, the utility of this method is severely limited by the day-to-day variability in host egg excretion in the stool. In high-transmission areas, the point-of-care circulating cathodic antigen (POC-CCA) urine assay has proven to be a reliable test. However, investigations...
متن کاملEvaluation and optimization of the Circulating Cathodic Antigen (POC-CCA) cassette test for detecting Schistosoma mansoni infection by using image analysis in school children in Mwanza Region, Tanzania
There is a need for diagnostic techniques which are sensitive, specific, rapid and easy to perform at the point-of-care. The aim of this study was to evaluate the diagnostic performance of the Circulating Cathodic Antigen (POC-CCA) assay for Schistosoma mansoni in four schools along the coast of Lake Victoria in Mwanza Region, Tanzania, and to optimize the reading of the POC-CCA test lines by u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista da Sociedade Brasileira de Medicina Tropical
دوره 49 3 شماره
صفحات -
تاریخ انتشار 2016