Controlling residual hydrogen gas in mass spectra during pulsed laser atom probe tomography
نویسنده
چکیده
Residual hydrogen (H2) gas in the analysis chamber of an atom probe instrument limits the ability to measure H concentration in metals and alloys. Measuring H concentration would permit quantification of important physical phenomena, such as hydrogen embrittlement, corrosion, hydrogen trapping, and grain boundary segregation. Increased insight into the behavior of residual H2 gas on the specimen tip surface in atom probe instruments could help reduce these limitations. The influence of user-selected experimental parameters on the field adsorption and desorption of residual H2 gas on nominally pure copper (Cu) was studied during ultraviolet pulsed laser atom probe tomography. The results indicate that the total residual hydrogen concentration, HTOT, in the mass spectra exhibits a generally decreasing trend with increasing laser pulse energy and increasing laser pulse frequency. Second-order interaction effects are also important. The pulse energy has the greatest influence on the quantity HTOT, which is consistently less than 0.1 at.% at a value of 80 pJ.
منابع مشابه
Optimization of Experimental Parameters and Specimen Geometry for PulsedLaser Atom-Probe Tomography of Copper
Copper (Cu) is a commercially important material used in semiconductor devices and other nanostructured materials. The accurate characterization of nano-scale deposition layers, dopant distributions, and impurity concentrations in Cu is of fundamental importance for the continued development of nanostructured materials. One quantitative compositional analysis technique that has the requisite su...
متن کاملA model Ni-Al-Mo superalloy studied by ultraviolet pulsed-laser-assisted local-electrode atom-probe tomography.
This study investigates the effects of the charge-state ratio of evaporated ions on the accuracy of local-electrode atom-probe (LEAP) tomographic compositional and structural analyses, which employs a picosecond ultraviolet pulsed laser. Experimental results demonstrate that the charge-state ratio is a better indicator of the best atom-probe tomography (APT) experimental conditions compared wit...
متن کاملAtom probe tomography of a-axis GaN nanowires: analysis of nonstoichiometric evaporation behavior.
GaN nanowires oriented along the nonpolar a-axis were analyzed using pulsed laser atom probe tomography (APT). Stoichiometric mass spectra were achieved by optimizing the temperature, applied dc voltage, and laser pulse energy. Local variations in the measured stoichiometry were observed and correlated with facet polarity using scanning electron microscopy. Fewer N atoms were detected from nonp...
متن کاملUltrafast Laser Assisted Field Evaporation and Atom Probe Tomography Applications
Considering the recent developments of the pulsed laser in the femtosecond domain, the possibility of conceiving a new laser assisted Tomographic Atom Probe has been nvisaged. The instrument is able to map out the 3D distributions of the atomic positions in a The interest of the terial sciences has already been demonstrated many times [3,4]. However, since HV mples have to be electrically good ...
متن کاملFT - ICR Study of Chemical Reaction of Silicon Clusters
Chemical reaction of small silicon cluster ions Sin (11 ≤ n ≤ 20) with ethylene was studied with a newly implemented Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. Silicon clusters were generated by a pulsed laser-vaporization supersonic-expansion cluster beam source directly connected to FT-ICR spectrometer. Injected and size selected silicon clusters were thermalized to...