ACETEST ASCORBATE (ASCORBIC ACID) BILIRUBIN CHROMOGENS CLINITEST GLYCOSURIA HEMATURIA HEMOGLOBINURIA ICTOTEST KETONES LEUKOCYTE ESTERASE MYOGLOBIN NITRITE pH PROTEIN PROTEIN ERROR OF INDICATORS PROTEINURIA REAGENT STRIP REDUCING SUBSTANCE RUN-OVER TAMM–HORSFALL PROTEIN UROBILINOGEN
ثبت نشده
چکیده
1. Describe the principle and procedure. 2. Compare and contrast reagent strip characteristics among manufacturers. 3. Interpret results. 4. Define expected normal values. 5. Suggest causes for abnormal findings. 6. Identify sources of error. 7. Suggest appropriate confirmatory tests. 8. Correlate results of chemical tests with those of physical examination. 9. Predict findings of microscopic examination.
منابع مشابه
URINE REAGENT STRIPS FOR URINALYSIS For the Semi-quantitative and qualitative detection of Glucose, Bilirubin, Ketone, Specific Gravity, Blood, pH, Protein, Urobilinogen, Nitrite, Leukocytes and Ascorbic Acid in Urine
1 TUP for Urinalysis are firm plastic strips to which several different reagent areas are affixed. Depending on the product being used, TUP provide tests for Glucose, Bilirubin, Ketone (Acetoacetic acid), Specific Gravity, Blood, pH, Protein, Urobilinogen, Nitrite, Leukocytes, and Ascorbic Acid in Urine. Test results may provide information regarding the status of carbohydrate 1,2 metabolism, k...
متن کاملUrine Reagent Strips for Urinalysis
This Package Insert to be used with the following products: • URS-1B • URS-1G • URS-1P • URS-1K • URS-2K • URS-2P •URS-2LP • URS-3 • URS-4B • URS-4S • URS-5K • URS-5U • URS-6 • URS-6L • URS-7 • URS-8 • URS-9 • URS-10 • URS-11 For the semi-quantitative and qualitative detection of Glucose, Bilirubin, Ketone, Specific Gravity, Blood, pH, Protein, Urobilinogen, Nitrite, Leukocytes and Ascorbic Aci...
متن کاملEvaluation of Aution Max AX-4280 automated urine test-strip analyser.
Aution Max AX-4280, an automated urine test-strip analyser, was evaluated in three centres. Method comparison, imprecision, carry-over, linearity, detection limit and drift studies were performed for glucose, protein, blood and leukocytes using Uriflet S 9UB strips. These strips enable measurement of pH, glucose, protein, blood, leukocytes, ketones, bilirubin, urobilinogen and nitrite. Specific...
متن کاملEvaluation of Ames' "Clini-Tek".
Reproducibility of reading "N-Multistix" dipsticks by a semi-automated urinalysis instrument (Ames' "Clini-Tek") has been described for artifically prepared samples. Glucose, ketone, urobilinogen, and nitrite showed high reproducibility (greater than 90%) for reading multiple samples at predetermined analyte concentrations. Determination of proteinuria showed the lowest proportion of false posi...
متن کاملEffects of Escherichia coli Infection on Some Serum and Urine Biochemical Parameters in Premenopausal and Postmenopausal Patients
The changes in some serum and urine biochemical parameters in Escherichia coli infected premenopausal and postmenopausal patients were studied. Blood specimens as well as early morning midstream urine specimens were collected from forty premenopausal patients aged 13-15 years, forty postmenopausal patients aged 45-60 years and twenty control subjects with no evidence of Escherichia coli infecti...
متن کامل