The impact of a point-of-care testing device on CVD risk assessment completion in New Zealand primary-care practice: A cluster randomised controlled trial and qualitative investigation
نویسندگان
چکیده
OBJECTIVES To assess the effect of a point of care (POC) device for testing lipids and HbA1c in addition to testing by community laboratory facilities (usual practice) on the completion of cardiovascular disease (CVD) risk assessments in general practice. METHODS We conducted a pragmatic, cluster randomised controlled trial in 20 New Zealand general practices stratified by size and rurality and randomised to POC device plus usual practice or usual practice alone (controls). Patients aged 35-79 years were eligible if they met national guideline criteria for CVD risk assessment. Data on CVD risk assessments were aggregated using a web-based decision support programme common to each practice. Data entered into the on-line CVD risk assessment form could be saved pending blood test results. The primary outcome was the proportion of completed CVD risk assessments. Qualitative data on practice processes for CVD risk assessment and feasibility of POC testing were collected at the end of the study by interviews and questionnaire. The POC testing was supported by a comprehensive quality assurance programme. RESULTS A CVD risk assessment entry was recorded for 7421 patients in 10 POC practices and 6217 patients in 10 control practices; 99.5% of CVD risk assessments had complete data in both groups (adjusted odds ratio 1.02 [95%CI 0.61-1.69]). There were major external influences that affected the trial: including a national performance target for CVD risk assessment and changes to CVD guidelines. All practices had invested in systems and dedicated staff time to identify and follow up patients to completion. However, the POC device was viewed by most as an additional tool rather than as an opportunity to review practice work flow and leverage the immediate test results for patient education and CVD risk management discussions. Shortly after commencement, the trial was halted due to a change in the HbA1c test assay performance. The trial restarted after the manufacturing issue was rectified but this affected the end use of the device. CONCLUSIONS Performance incentives and external influences were more powerful modifiers of practice behaviours than the POC device in relation to CVD risk assessment completion. The promise of combining risk assessment, communication and management within one consultation was not realised. With shifts in policy focus, the utility of POC devices for patient engagement in CVD preventive care may be demonstrated if fully integrated into the clinical setting. TRIAL REGISTRATION Australian New Zealand Clinical Trials Registry ACTRN12613000607774.
منابع مشابه
Updated protocol and guest participant results from the ACCeRT clinical study
Introduction: Cancer cachexia is a condition often seen at diagnosis, throughout chemotherapeutic treatments and in end stage Non-Small Cell Lung Cancer patients. These patients often experience a shorter life-expectancy and deterioration in performance status and reduced quality of life. New multi˗targeted regimens are required to be tested in this population to address these issues. Material...
متن کاملHepatitis C – Assessment to Treatment Trial (HepCATT) in primary care: study protocol for a cluster randomised controlled trial
BACKGROUND Public Health England (PHE) estimates that there are upwards of 160,000 individuals in England and Wales with chronic hepatitis C virus (HCV) infection, but until now only around 100,000 laboratory diagnoses have been reported to PHE and of these 28,000 have been treated. Targeted case-finding in primary care is estimated to be cost-effective; however, there has been no robust random...
متن کاملPoint-of-care testing to promote cardiovascular disease risk assessment: A proof of concept study
Updated cholesterol guidelines emphasize multivariable cardiovascular disease (CVD) risk estimation to guide treatment decision-making in primary prevention. This study tested the preliminary feasibility, acceptability and efficacy of point-of-care testing (POCT) and quantitative CVD risk assessment in high-risk adults to increase guideline-recommended statin use in primary prevention. Particip...
متن کاملAUtomated Risk Assessment for Stroke in Atrial Fibrillation (AURAS-AF) - an automated software system to promote anticoagulation and reduce stroke risk: study protocol for a cluster randomised controlled trial
BACKGROUND Patients with atrial fibrillation (AF) are at significantly increased risk of stroke. Oral anticoagulants (OACs) substantially reduce this risk, with gains seen across the spectrum of baseline risk. Despite the benefit to patients, OAC prescribing remains suboptimal in the United Kingdom (UK). We will investigate whether an automated software system, operating within primary care ele...
متن کاملThe Fremantle Primary Prevention Study: a multicentre randomised trial of absolute cardiovascular risk reduction.
BACKGROUND Cardiovascular disease (CVD) is the leading cause of global mortality. Risk factor management in clinical practice often relies on relative risk modification rather than the more appropriate absolute risk assessment. AIM To determine whether patients receiving more-frequently designated GP visits had increased benefit in terms of their absolute CVD risk assessment, as compared wit...
متن کامل