Effects of gold coating of coronary stents on neointimal proliferation following stent implantation.
نویسندگان
چکیده
Experimental studies suggest a reduced neointimal tissue proliferation in vascular stainless steel stents coated with gold. This prospective multicenter trial evaluated the impact of gold coating on neointimal tissue proliferation in patients undergoing elective stent implantation. The primary end point was the in-stent tissue proliferation measured by intravascular ultrasound at 6 months comparing stents of identical design with or without gold coating (Inflow). Two hundred four patients were randomized to receive uncoated (group A, n = 101) or coated (group B, n = 103) stents. Baseline parameters did not differ between the groups. Stent length and balloon size were comparable, whereas inflation pressure was slightly higher in group A (14 +/- 3 vs 13 +/- 3 atm, p = 0.013). Procedural success was similar (A, 97%; B, 96%). The acute angiographic result was better for group B (remaining stenosis 4 +/- 12% vs 10 +/- 11%, p = 0.002). Six-month examinations revealed more neointimal proliferation in group B. By ultrasound, the neointimal volume within the stent was 47 +/- 25 versus 41 +/- 23 mm(3) (p = 0.04), with a ratio of neointimal volume-to-stent volume of 0.45 +/- 0.12 versus 0.40 +/- 0.12 (p = 0.003). The angiographic minimal luminal diameter was smaller in group B (1.47 +/- 0.57 vs 1.69 +/- 0.70 mm, p = 0.04), with a higher late luminal loss of 1.17 +/- 0.51 versus 0.82 +/- 0.56 mm (p = 0.001). Thus, gold coating of the tested stent type resulted in more neointimal tissue proliferation.
منابع مشابه
[Randomized intravascular ultrasound comparison between endoprostheses with and without amorphous silicon-carbide].
The superiority of coronary stent implantation over percutaneous transluminal balloon angioplasty in virtually all lesion subsets has led to the wide use of stents for the percutaneous treatment of coronary lesions 1,2. However, in-stent restenosis remains as a major limitation 3,4. Recent data suggest that neointimal proliferation, the cornerstone of in-stent restenosis 5,6, is related to the ...
متن کاملPaclitaxel stent coating inhibits neointimal hyperplasia at 4 weeks in a porcine model of coronary restenosis.
BACKGROUND Despite limiting elastic recoil and late vascular remodeling after angioplasty, coronary stents remain vulnerable to restenosis, caused primarily by neointimal hyperplasia. Paclitaxel, a microtubule-stabilizing drug, has been shown to inhibit vascular smooth muscle cell migration and proliferation contributing to neointimal hyperplasia. We tested whether paclitaxel-coated coronary st...
متن کاملPaclitaxel balloon coating, a novel method for prevention and therapy of restenosis.
BACKGROUND Drug-eluting stents have shown promising antirestenotic effects in clinical trials. Non-stent-based local delivery of antiproliferative drugs may offer additional flexibility and also reach vessel areas beyond the immediate stent coverage. The aim of the present study was to evaluate a novel method of local drug delivery based on angioplasty balloons. METHODS AND RESULTS Stainless ...
متن کاملMethotrexate loaded SAE coated coronary stents reduce neointimal hyperplasia in a porcine coronary model.
OBJECTIVE To evaluate the effect of stent based methotrexate delivery on neointimal hyperplasia. METHODS Stainless steel coronary stents and biological polymer coated (SAE) stents were randomly implanted in coronary arteries of pigs with a stent to artery ratio of 1.1:1. The pigs were killed after five days (10 stents) or four weeks (20 stents). Second, stainless steel coronary stents were di...
متن کاملHuman recombinant activated protein C-coated stent for the prevention of restenosis in porcine coronary arteries
Activated protein C (APC), an endogenous protein, inhibits inflammation and thrombosis and interrupts the coagulation cascade. Here, we investigated the effect of human recombinant APC on the development of neointimal hyperplasia in porcine coronary arteries. Yukon Choice bare metal stents were coated with 2.6 µg APC/mm(2). Under general anesthesia, APC-coated and bare stents were implanted in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The American journal of cardiology
دوره 89 7 شماره
صفحات -
تاریخ انتشار 2002