Biomechanical comparison of headless antegrade screw versus retrograde cortical screw for coronoid fracture fixation.
نویسندگان
چکیده
OBJECTIVE Posterior-to-anterior directed screws are stronger than anterior-to-posterior directed screws for coronoid fracture fixation. Anterior approaches that facilitate direct reduction and fixation of coronoid fractures have been described. The present study was based on the hypothesis that anterior-to-posterior headless screw (Acutrak Mini® 3.5 mm × 26 mm, Acumed, Hillsboro, Oregon, USA) fixation of coronoid fractures would be as strong as posterior-to-anterior 2.7 mm Association for Osteosynthesis (AO) cortical screw fixation. METHODS This study included 14 ulnas obtained from 14 formalin-preserved adult cadavers. Coronoid type 2 fractures were created and fixed randomly using anterior-to-posterior headless screws (antegrade group) and posterior-to-anterior 2.7 mm AO cortical screws (retrograde group). The experimental constructs were loaded until 2 mm of displacement. Failure load (N), fixation stiffness (Nmm-1), and indentation stiffness were calculated. RESULTS Failure load was higher in the retrograde screw group (p=0.03), whereas loading stiffness values of the fixation devices and bones did not differ between the 2 fixation groups (p>0.05). CONCLUSION The present study failed to show that anterior-to-posterior directed headless screw fixation of coronoid fractures could adequately replace posterior-to-anterior placed screw fixation.
منابع مشابه
Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery
Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...
متن کاملScrew fixation versus arthroplasty versus plate fixation for 3-part radial head fractures.
PURPOSE To compare the outcome following headless compression screw fixation versus radial head arthroplasty versus plate fixation for 3-part Mason types III or IV radial head fracture. METHODS Records of 25 men and 16 women aged 21 to 80 (mean, 43.3) years who underwent fixation using 2 to 3 2-mm cannulated headless compression screws (n=16), radial head arthroplasty (n=13), or fixation with...
متن کاملA Biomechanical Comparison of Repair Techniques for Anterior Cruciate Ligament Avulsionfracture under Cyclic Loading
INTRODUCTION Failed treatment for avulsion fracture of the tibial attachment of the anterior cruciate ligament (ACL) leads to anterior knee instability when the avulsion fragment is displaced. Anatomical reduction and fixation of the fragment are widely recommended for type III and IV displaced fracture. Although several surgical techniques for arthroscopic reduction and internal fixation (ARIF...
متن کاملBiomechanical Comparison of Inter-fragmentary Compression Pressures: Lag Screw versus Herbert Screw for Anterior Odontoid Screw Fixation
OBJECTIVE The purpose of the present study was to compare inter-fragmentary compression pressures after fixation of a simulated type II odontoid fracture with the headless compression Herbert screw and a half threaded cannulated lag screw. METHODS We compared inter-fragmentary compression pressures between 40- and 45-mm long 4.5-mm Herbert screws (n=8 and n=9, respectively) and 40- and 45-mm ...
متن کاملCannulated screw versus Kirschner-wire fixation for Milch II lateral condyle fractures in a paediatric sawbone model: a biomechanical comparison
Purpose Lateral condyle fractures of the humerus are common in the paediatric population, accounting for up to 20% of elbow fractures. Traditional management involves internal fixation with Kirschner (K)-wires, however, this has been associated with complications and insufficiently rigid fixation. Recently, cannulated screws have been proposed as a more stable method of fixation. While cannulat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta orthopaedica et traumatologica turcica
دوره 49 3 شماره
صفحات -
تاریخ انتشار 2015