Effect of algorithm aggressiveness on the performance of the Hypoglycemia-Hyperglycemia Minimizer (HHM) System.
نویسندگان
چکیده
The Hypoglycemia-Hyperglycemia Minimizer (HHM) System aims to mitigate glucose excursions by preemptively modulating insulin delivery based on continuous glucose monitor (CGM) measurements. The "aggressiveness factor" is a key parameter in the HHM System algorithm, affecting how readily the system adjusts insulin infusion in response to changing CGM levels. Twenty adults with type 1 diabetes were studied in closed-loop in a clinical research center for approximately 26 hours. This analysis focused on the effect of the aggressiveness factor on the insulin dosing characteristics of the algorithm and, to a lesser extent, on the glucose control results observed. As the aggressiveness factor increased from conservative to medium to aggressive: the maximum observed insulin dose delivered by the algorithm—which is designed to give doses that are corrective in nature every 5 minutes—increased (1.00 vs 1.15 vs 2.20 U, respectively); tendency to adhere to the subject's nominal basal dose decreased (61.9% vs 56.6% vs 53.4%); and readiness to decrease insulin below basal also increased (18.4% vs 19.4% vs 25.2%). Glucose analyses by both CGM and Yellow Springs Instruments (YSI) indicated that the aggressive setting of the algorithm resulted in the least time spent at levels >180 mg/dL, and the most time spent between 70-180 mg/dL. There was no severe hyperglycemia, diabetic ketoacidosis, or severe hypoglycemia for any of the aggressiveness values investigated. These analyses underscore the importance of investigating the sensitivity of the HHM System to its key parameters, such as the aggressiveness factor, to guide future development decisions.
منابع مشابه
Closed-Loop Control Performance of the Hypoglycemia-Hyperglycemia Minimizer (HHM) System in a Feasibility Study.
BACKGROUND This feasibility study investigated the insulin-delivery characteristics of the Hypoglycemia-Hyperglycemia Minimizer (HHM) System-an automated insulin delivery device-in participants with type 1 diabetes. METHODS Thirteen adults with type 1 diabetes were enrolled in this nonrandomized, uncontrolled, clinical-research-center-based feasibility study. The HHM System comprised a contin...
متن کاملEffect of various blood glucose levels on regional FDG uptake in the brain
Objective(s): Studies have mainly assessed the effect of hyperglycemia on18F-fluorodeoxyglucose (FDG) uptake in the brain. In this study, we assessed the FDG uptake of the brain not only in normo- and hyperglycemia but also in hypoglycemia to compare the effect of various blood glucose levels on regional FDG uptake in the brain. Methods: </...
متن کاملModified Convex Data Clustering Algorithm Based on Alternating Direction Method of Multipliers
Knowing the fact that the main weakness of the most standard methods including k-means and hierarchical data clustering is their sensitivity to initialization and trapping to local minima, this paper proposes a modification of convex data clustering in which there is no need to be peculiar about how to select initial values. Due to properly converting the task of optimization to an equivalent...
متن کاملLoad Model Effect Assessment on Optimal Distributed Generation Sizing and Allocation Using Improved Harmony Search Algorithm
The operation of a distribution system in the presence of distributed generation systems has someadvantages and challenges. Optimal sizing and siting of DG systems has economic, technical, andenvironmental benefits in distribution systems. Improper selection of DG systems can reduce theseadvantages or even result in deterioration in the normal operation of the distribution system. DGallocation ...
متن کاملUsing the Particle Swarm Optimization Algorithm to Generate the Minimum Test Suite in Covering Array with Uniform Strength
Up to now, several useful algorithms have been proposed to generate covering array, which is one of the branches of combinatorial testing. The main challenge in generating such arrays is generation of the arrays with a minimum number of test cases (for efficiency) at a proper time (for performance), for large systems. Covering array generation strategies are often divided into two general categ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of diabetes science and technology
دوره 8 4 شماره
صفحات -
تاریخ انتشار 2014