Sophisticated test objects for the quality assurance of optical computed tomography scanners.
نویسندگان
چکیده
Optical computed tomography (CT), in conjunction with radiochromic gels and plastics, shows great potential for radiation therapy dose verification in 3D. However, an effective quality assurance (QA) regime for the various scanners currently available still remains to be developed. We show how the favourable properties of the PRESAGE® radiochromic polymer may be exploited to create highly sophisticated QA phantoms. Five 60 mm diameter cylindrical PRESAGE® samples were irradiated using the x-ray microbeam radiation therapy facility on the ID-17 biomedical beamline at the European Synchrotron Radiation Facility. Samples were then imaged on the University of Surrey parallel-beam optical CT scanner. The sample irradiations were designed to allow a variety of tests to be performed, including assessments of linearity, modulation transfer function (three independent measurements), geometric distortion and the effect of treatment fractionation. It is clear that, although the synchrotron method produces extremely high-quality test objects, it is not practical on a routine basis, because of its reliance on a highly specialized radiation source. Hence, we investigated a second possibility: three PRESAGE® samples were illuminated with ultraviolet light of wavelength 365 nm, using cheap masks created by laser-printing patterns onto overhead projector acetate sheets. There was good correlation between optical densities measured by the CT scanner and the expected UV 'dose' delivered. The results are encouraging and a proposal is made for a scanner test regime based on calibrated and well-characterized PRESAGE® samples.
منابع مشابه
Estimation of diagnostic reference levels for children computed tomography: A study in Tehran, Iran
Background: The Diagnostic reference levels (DRLs) play a critical role in the optimization of radiation dose especially, in some conditions like pediatrics. They are useful indicators by which the radiologists can be aware of delivered excess radiation doses to the patients, and take corrective actions if necessary. In order to meet some requirements for establishing the national computed tomo...
متن کاملA local study on diagnostic reference levels estimation for children computed tomography
Introduction: The Diagnostic reference levels (DRLs) play a critical role in the optimization of radiation dose especially, in some conditions like pediatrics. They are useful indicators by which the radiologists can be aware of delivered excess radiation doses to the patients, and take corrective actions if necessary. In order to meet some requirements for establishing the nat...
متن کاملOptimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality
Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...
متن کاملValidation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners
Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...
متن کاملEvaluation of the gray level in CBCT systems and its relationship with HU in CT Scanners
Introduction: Cone-beam CT (CBCT) is an imaging system which offers three-dimensional (3D), multiplanar images and has many advantages over computed tomography (CT) including shorter acquisition times for the resolution desired in dentistry, lower radiation dose to the patient, reasonable price and higher spatial resolution but CBCT scanners are unable to display actual Hounsf...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 56 14 شماره
صفحات -
تاریخ انتشار 2011