Successful treatment of a ruptured spontaneous dissecting coronary artery pseudoaneurysm with a covered stent in a patient with cardiac tamponade.
نویسندگان
چکیده
The rupture of spontaneous dissecting coronary artery pseudoaneurysms is rare, and no standard therapy has yet been established for this condition. This report describes a case of a ruptured spontaneous dissecting coronary artery pseudoaneurysm in a patient with cardiac tamponade that was successfully treated with emergent implantation of a covered stent.
منابع مشابه
Diagnosis and Treatment of Spontaneous Coronary Artery Pseudoaneurysm
Spontaneous coronary artery pseudoaneurysm (PSA, false aneurysm) is an extremely rare occurrence with the precise incidence unknown. It is defined as an outwardly bulging monolayer or double layer within the coronary artery that lacks all 3 layers (intima, media, and adventitia) of the arterial wall. Coronary PSA commonly occurs from arterial dissection or perforation induced by catheter interv...
متن کاملA patient with myocardial infarction and tamponade as a result of spontaneous rupture of an ectatic coronary artery
Introduction: Spontaneous rupture of ectatic vessels is possible in different vascular beds and it can be life-threatening. Rapid diagnosis and initiation of appropriate treatment are essential. Case report: A 63-year-old man presented with chest pain in a state where he was sleepy. Vital signs at the time of admission included a systemic blood pressure of 90/70 mm Hg, heart rate of 100 beats p...
متن کاملManagement of a large coronary artery aneurysm with graft-coated stent during the acute phase of myocardial infarction
Coronary aneurysms in adults are rare clinical entities. Herein, we presented a 54-year-old man who was admitted with an acute extensive anterior myocardial infarction. The emergency coronary angiography revealed an isolated large aneurysm at the proximal segment of the left anterior descending coronary artery. The patient was successfully treated with a graft-coated stent
متن کاملCoronary Artery Perforation and Regrowth of a Side Branch Occluded by a Polytetrafluoroethylene-Covered Stent Implantation
Stenting of the right coronary artery stenosis caused coronary perforation and profound dye (blood) extravasation in a 69-year-old female patient. Instantaneous balloon inflation followed by implantation of a polytetrafluoroethylene- (PTFE-)covered stent sealed the coronary perforation, restored the blood flow, and perceivably caused acute occlusion of a large side branch (SB). The immediate in...
متن کاملSuccessful management of Ellis type III left anterior descending artery perforation following percutaneous coronary intervention by a covered stent: Successfully resolved the dramatic complication.
Coronary artery perforation is a rare but catastrophic complication of percutaneous coronary intervention (PCI). Grade III coronary perforation and rupture invariably results in pericardial effusion and tamponade requiring urgent pericardiocentesis. Advances in coronary intervention have increased the opportunity to treat coronary artery perforation. We are reporting a case of 55 years old hype...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Internal medicine
دوره 53 10 شماره