Results from Terrasar-x Geometric and Radiometric Calibration

نویسندگان

  • B. Bräutigam
  • M. Schwerdt
  • M. Bachmann
  • B. Döring
چکیده

As TerraSAR-X, due for launch in June 2007, will be an operational scientific mission with commercial potential, product quality is of crucial importance. The success or failure of the mission essentially depends on the calibration of the TerraSAR-X system ensuring the product quality and the correct in-orbit operation of the entire SAR system. This paper describes the calibration procedures for TerraSAR-X and the dedicated activities to be performed during the five months commissioning phase. Results from on-ground tests are discussed with respect to geometric and radiometric calibration of the TerraSAR-X system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Geometric Calibration and Radiometric Correction of LiDAR Data and Their Impact on the Quality of Derived Products

LiDAR (Light Detection And Ranging) systems are capable of providing 3D positional and spectral information (in the utilized spectrum range) of the mapped surface. Due to systematic errors in the system parameters and measurements, LiDAR systems require geometric calibration and radiometric correction of the intensity data in order to maximize the benefit from the collected positional and spect...

متن کامل

Geometric, Radiometric, Polarimetric and Along-Track Interfer- ometric Calibration of the new F-SAR system of DLR in X-Band

Since November 2006, DLR operates F-SAR a new airborne SAR sensor beside its experimental airborne SAR sensor E-SAR. F-SAR is a totally new development utilizing most modern hardware. It is presently operated in X-band and has been supplemented recently being fully polarimetric. F-SAR already accomplished several flights and acquired SAR data in different operation modes, amongst others in alon...

متن کامل

A novel Radargrammetric Model and a RPCs Generation Strategy: Application with COSMO-SkyMed and Terra SAR-X Imagery

The topic of this paper is the definition of a geometric model for stereo pair orientation of SpotLight Synthetic Aperture Radar (SAR) imagery collected by the new high amplitude resolution radar sensors COSMO-SkyMed (Italian) and TerraSAR-X (German). The suite for radargrammetric approach has been implemented in SISAR (Software per Immagini Satellitari ad Alta Risoluzione), a scientific softwa...

متن کامل

Terrasar-x Data for Improving Geometric Accuracy of Optical High and Very High Resolution Satellite Data

Most high resolution optical images from space need ground control information (GCP) before an orthorectification can be performed. The very high geometric accuracy of geocoded data of the TerraSAR-X satellite has been shown in several investigations. This precision has been reached fully automatically without any GCP and is due to good sensor calibration, high accuracy of satellite position an...

متن کامل

Outdoor Rcs Measurement Range for Spaceborne Sar Calibration Targets

The Microwaves and Radar Institute regularly performs calibration campaigns for spaceborne synthetic aperture radar (SAR) systems, among which have been X-SAR, SRTM, and ASAR. Tight performance specifications for future spaceborne SAR systems like TerraSAR-X and TanDEM-X demand an absolute radiometric accuracy of better than 1 dB. The relative and absolute radiometric calibration of SAR systems...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007