Bending moments and types of failure of zirconia and titanium abutments with internal implant-abutment connections: a laboratory study.
نویسندگان
چکیده
PURPOSE The aim of this study was to examine the bending moments and fracture patterns of different zirconia abutments with internal implant-abutment connections after static loading and to compare their bending moments to those of internally connected titanium abutments. MATERIALS AND METHODS Three types of customized zirconia abutments (Straumann CARES abutments/Straumann BL implants [T1], Astra ZirDesign abutments/Astra Micro Thread OsseoSpeed implants [T2], Zirabut prototype abutments/Straumann SP implants [T3]) and one type of customized titanium abutment (control group, Straumann CARES abutments/Straumann BL implants [C]) were included. All abutments were one-piece abutments with an internal implant-abutment connection and were customized to the same shape but featured different implant-abutment connection designs. For each group, 20 identical copies of a master abutment were fabricated and fixed on their corresponding implants. Half of the abutments in each group were left unrestored, and the other 10 received glass-ceramic crowns. Static loading was applied at a 30-degree angle to the palatal surface until failure, and bending moments were calculated. The type of failure was characterized visually by dismounting the abutments and by examination of cross-sections of the embedded specimens. The results were analyzed statistically. RESULTS The mean range of bending moments was higher for the unrestored groups (158.2 to 678.2 Ncm) than for the restored groups (117.9 to 419.4 Ncm). The highest mean bending moments were seen in the control group, both restored and unrestored (419.4/678.2 Ncm). Unrestored, T1 and T2 exhibited significantly higher bending moments than T3. This was also observed in the restored groups. CONCLUSION Both the abutment material and the implant-abutment connection design affected the bending moments of abutments after static loading. Internally connected zirconia abutments with horizontal mismatch to the implant exhibited significantly higher bending moments compared to those without horizontal mismatch.
منابع مشابه
Bending moments of zirconia and titanium implant abutments supporting all-ceramic crowns after aging.
OBJECTIVES To test the fracture load and fracture patterns of zirconia abutments restored with all-ceramic crowns after fatigue loading, exhibiting internal and external implant-abutment connections as compared to restored and internally fixed titanium abutments. MATERIALS AND METHODS A master abutment was used for the customization of 5 groups of zirconia abutments to a similar shape (test)....
متن کاملمقایسه مقاومت شکست و نوع شکست اباتمنتهای زیرکونیایی مختلف در مقایسه با اباتمنتهای تیتانیومی
Background and Aims: One of the decisive factors on the final esthetic results of implant treatment is the abutment material. Ceramic abutments are nowadays very popular in this regard. The purpose of this study was to compare the fracture resistance of three zirconia abutments with titanium abutment. Materials and Methods: Four groups of abutments (five specimens in each) were prepared. The a...
متن کاملComparative Evaluation of Microgap at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study
Abstract Background and Aim : Microgap in the implant-abutment interface is one of the main challenges in the treatment of two-piece implants. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microgap at implant-abutment interface area under oblique cyclic loading in vitro. Methods and Materials In this in vitro study, 12 implant-abutment assemb...
متن کاملComparative Evaluation of Microleakage at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study
Abstract Background and aim: Oral microbiota could proliferate the microspace between the implant and abutment, thereby cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microleakage at implant-abutment interface area under oblique cyclic loading in vitro. Materials and methods:In thi...
متن کاملEvaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro
Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The International journal of oral & maxillofacial implants
دوره 27 3 شماره
صفحات -
تاریخ انتشار 2012