Loop-mediated isothermal amplification assay for rapid diagnosis of malaria infections in an area of endemicity in Thailand.

نویسندگان

  • Jetsumon Sattabongkot
  • Takafumi Tsuboi
  • Eun-Taek Han
  • Sirasate Bantuchai
  • Sureemas Buates
چکیده

The loop-mediated isothermal amplification (LAMP) method, developed by our group for diagnosis of four human malaria parasites, was evaluated on a large scale at a remote clinic in Thailand where malaria is endemic. A total of 899 febrile patients were analyzed in this study. LAMP was first evaluated in 219 patients, and the result was compared to those of two histidine-rich protein (HRP)-2 rapid diagnostic tests (RDTs) and microscopy as a gold standard. LAMP DNA extraction was conducted by a simple boiling method, and the test results were assessed visually. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 95.7%, 100%, 100%, and 98%, respectively, for LAMP and 98.6%, 98%, 95.8%, and 99.3%, respectively, for RDTs. Since RDT-positive results were based on one out of two RDTs, the sensitivity of RDTs was slightly higher than that of LAMP. However, LAMP tended to be more specific than RDTs. LAMP next was evaluated in 680 patients, and the result was compared to that of microscopy as a gold standard. Sensitivity, specificity, PPV, NPV, and diagnostic accuracy of LAMP were 88.9%, 96.9%, 92.2%, 95.5%, and 94.6%, respectively. Nested PCR was used to confirm the discrepant results. Malaria LAMP in a remote clinic in Thailand achieved an acceptable result, indicating that LAMP malaria diagnosis is feasible in a field setting with limited technical resources. Additionally, the rapid boiling method for extracting DNA from dried blood spots proved to be simple, fast, and suitable for use in the field.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Loop-Mediated Isothermal Amplification (LAMP) for the Rapid Diagnosis of Herpes Simplex Virus Type 1 (HSV-1)

Background and Aims: considering difficulties in usual laboratory methods in detection of viral infections, improved DNA-based diagnostic techniques are more reliable. Loop mediated isothermal amplification method (LAMP) is a nucleic acid amplification method that amplifies DNA using six primers which has been developed to diagnose viruses as a rapid and high efficiency test. In this study, the...

متن کامل

A reverse transcriptase-loop mediated isothermal amplification assay (RT-LAMP) for rapid detection of bovine viral diarrhea virus 1 and 2

Bovine viral diarrhea virus (BVDV) is a pathogen that infects cattle, and is globally important. It causes substantial financial losses to the livestock industry. In the current study, a one-step reverse transcriptase-loop-mediated isothermal amplification (RT-LAMP) assay was set up for rapid and efficient detection of BVDV. For this purpose, four primers were designed to recognize six distinct...

متن کامل

Rapid detection of infectious bursal disease by loop-mediated isothermal amplification for field analysis

Infectious bursal disease (IBD) is an immunosuppressive, acute and highly contagious illness of growing-poultry stock infected with infectious bursal disease virus (IBDV). It is common in Pakistan, causing potential economic losses throughout the year. The objective of the study is to propose a rapid, sensitive and specific diagnostic tool, and compare it with existing commonly used reverse tra...

متن کامل

Evaluation of a new rapid molecular diagnostic system for Plasmodium falciparum combined with DNA filter paper, loop-mediated isothermal amplification, and melting curve analysis.

Falciparum malaria is a fatal infection without immediate diagnosability or treatment. There are shortages of clinicians and examiners skilled in the treatment of malaria in non-endemic countries, including Japan. This study was performed to evaluate a novel rapid molecular diagnostic system consisting of loop-mediated isothermal amplification (LAMP) combined with DNA filter paper (FTA card) an...

متن کامل

Evaluation of the Loop Mediated Isothermal DNA Amplification (LAMP) Kit for Malaria Diagnosis in P. vivax Endemic Settings of Colombia

BACKGROUND Most commonly used malaria diagnostic tests, including microscopy and antigen-detecting rapid tests, cannot reliably detect low-density infections which are frequent in low transmission settings. Molecular methods such as polymerase chain reaction (PCR) are highly sensitive but remain too laborious for field deployment. In this study, the applicability of a malaria diagnosis kit base...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 52 5  شماره 

صفحات  -

تاریخ انتشار 2014