Improved sample preparation for accurate determination of low concentrations of lead in whole blood by graphite furnace analysis.
نویسندگان
چکیده
The effect of low concentrations of lead on pre- and post-natal growth and development is a current concern. We describe a simple method of sample preparation for direct determination of lead in whole blood by Zeeman graphite-furnace atomic absorption spectrometry. This procedure improves analytical precision and accuracy of lead determinations at low concentrations as compared with published furnace data. At blood lead concentrations of 0.25, 1.98, and 3.76 mumol/L, within-run CVs were 3.2%, 1.8%, and 1.4% respectively; between-run CVs were 7.3%, 2.9%, and 2.2%. Accuracy, as demonstrated by analytical recovery, ranged from 99% to 102%. Our reproducibility/accuracy score in the 1989 Quebec interlaboratory comparison program was 96% compared with the target, second best of 66 participating laboratories.
منابع مشابه
Rapid ultramicro direct determination of erythrocyte lead concentration by atomic absorption spectrophotometry, with use of a graphite-tube furnace.
We describe a convenient, sensitive, accurate, precise and direct method for lead analysis in blood by use of the graphite-tube furnace with an atomic absorption spectrophotometer. Advantages of this proposed method are the ultramicro sample size and the minimal sample preparation required. Interferences by the major cations and anions in blood were studied and minimized. Anticoagulants examine...
متن کاملElectrochemical determination of low blood lead concentrations with a disposable carbon microarray electrode.
Lead concentrations in blood samples typical of unexposed individuals are determined by using square-wave anodic stripping voltammetry at a disposable 287-element (15-35-microns diameter) carbon microarray electrode. Analysis of a series of low Pb-containing samples (blood [Pb] = 17 to 92 micrograms/L) by standard addition gives good accuracy (average bias vs graphite furnace atomic absorption ...
متن کاملDetermination of Trace Elements in Rice Products by Flame and Graphite Furnace Atomic Absorption Spectrometry
The Thermo Scientific iCE 3000 Series Atomic Absorption Spectrometers are the ideal tool for the accurate and rapid determination of multiple trace elements in rice products. Flame atomic absorption can be used as a fast screening tool for the analysis of nutritional elements such as copper, manganese and zinc, while graphite furnace atomic absorption can be used for the accurate determination ...
متن کاملElimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry
A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...
متن کاملGRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY WITH MAlIlRIX MODIFICATION FOR DETERMINATION OF LEAD IN DRINKING WATER
An amoniumvanadate plus sodium molybdate mixed modifier Graphite Furnace Atomic Absorption Spectrometric method has been developed for determination of traces of lead in drinking water. The concentration of lead in the sample is obtained by direct comparison to linear working graph prepared from aqueous standards in the modifier medium, The results indicate the better performance of the pro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 37 4 شماره
صفحات -
تاریخ انتشار 1991