Characteristics of Anisometropic Patients with and without Strabismus
نویسندگان
چکیده
Objectives To evaluate the risk factors for strabismus in patients with anisometropia by comparing degree of anisometropia, depth of amblyopia, and binocular visual function in anisometropic patients with and without strabismus. Materials and Methods Sixty-five anisometropic patients older than 5 years with amblyopia in one eye who were followed in the Ankara University Faculty of Medicine, Department of Ophthalmology, Pediatric Ophthalmology and Strabismus Unit between May 2009 and April 2010 were included in this study. There were 27 cases of strabismus. The depth of amblyopia, degree of anisometropia, and binocular visual function were assessed in anisometropic cases with and without strabismus. Results The 65 patients with anisometropia were divided into two groups: 27 patients with strabismus (group 1) and 38 patients without (group 2). Depth of amblyopia was greater in patients with strabismus compared to those without (p=0.006). In patients with strabismus, there was no correlation between angle of deviation and depth of amblyopia (p=0.453). In anisometropic amblyopia patients without strabismus, there was a positive correlation between depth of anisometropia and depth of amblyopia (p=0.35, Pearson's correlation coefficient=0.343). Comparison in terms of anisometropia showed that patients with strabismus had significantly larger spherical difference between the two eyes than in patients without strabismus (p=0.000, Mann-Whitney U test). There was no significant difference in terms of cylindrical values (p=0.146, Mann-Whitney U test). There was no statistically significant difference in the presence of fusion between anisometropic patients with and without strabismus. Conclusion The risk of developing strabismus increased as degree of anisometropia increased in anisometropic cases. In addition, depth of amblyopia was greater in anisometropic patients with strabismus.
منابع مشابه
Rapid, high-accuracy detection of strabismus and amblyopia using the pediatric vision scanner.
Purpose. The Pediatric Vision Scanner (PVS) detects strabismus by identifying ocular fixation in both eyes simultaneously. This study was undertaken to assess the ability of the PVS to identify patients with amblyopia or strabismus, particularly anisometropic amblyopia with no measurable strabismus. Methods. The PVS test, administered from 40 cm and requiring 2.5 seconds of attention, generated...
متن کاملAnisometropic Amblyopia: Nonsurgical Treatment
Anisometropic amblyopia is characterized by a decrease in best corrected visual acuity in one eye as a result of significantly different refractive errors between the two eyes. The eye that ultimately provides a more blurred image to the visual cortex develops amblyopia.1 Several authors have suggested that anisometropia is the leading cause of amblyopia and is responsible for approximately 50%...
متن کاملUnusual Presentation of Hypertropia in a Case of Anisometropic Heavy Eye Syndrome
Purpose: To report the presence of hypertropia with esotropia in the case of anisometropic Heavy Eye Syndrome (HES). Case Report: A 33-years old lady referred to the strabismus clinic for evaluation. The patientchr('39')s esotropia started at the age of 12 and gradually increased. Corrected visual acuity was 2/10 and 4/100 and refraction was -24-3.25×103 and -10.25-0.75× 34 in the right and lef...
متن کاملComparison between anisometropic and strabismic amblyopia using functional magnetic resonance imaging.
AIMS To assess calcarine activation with functional magnetic resonance imaging (fMRI) in patients with anisometropic and strabismic amblyopia. METHODS 14 amblyopes (eight anisometropic and six strabismic) were studied with fMRI using stimuli of checkerboards of various checker sizes and temporal frequencies. While T2* weighted MRI were obtained every 3 seconds for 6 minutes, patients viewed t...
متن کاملEffects of strabismic amblyopia and strabismus without amblyopia on visuomotor behavior, I: saccadic eye movements.
PURPOSE It has previously been shown that anisometropic amblyopia affects the programming and execution of saccades. The aim of the current study was to investigate the impact of strabismic amblyopia on saccade performance. METHODS Fourteen adults with strabismic amblyopia, 13 adults with strabismus without amblyopia, and 14 visually normal adults performed saccades and reach-to-touch movemen...
متن کامل