Sensing metabolites using donor–acceptor nanodistributions in fluorescence resonance energy transfer
نویسندگان
چکیده
Before fluorescence sensing techniques can be applied to media as delicate and complicated as human tissue, an adequate interpretation of the measured observables is required, i.e., an inverse problem needs to be solved. Recently we have solved the inverse problem relating to the kinetics of fluorescence resonance energy transfer ~FRET!, which clears the way for the determination of the donor–acceptor distribution function in FRET assays. In this letter this approach to monitoring metabolic processes is highlighted and the application to glucose sensing demonstrated. © 2001 American Institute of Physics. @DOI: 10.1063/1.1367308#
منابع مشابه
A method of determining donor–acceptor distribution functions in Forster resonance energy transfer
We describe a method of determining the distribution function associated with acceptors partaking in Forster resonance ̈ Ž . energy transfer FRET from excited donors. Unlike previous approaches to this problem the method described makes no a priori assumption about the nature of the distribution. The use of an acceptor distribution function in analyte sensing is demonstrated for the first time. ...
متن کاملModulation of Intracellular Quantum Dot to Fluorescent Protein Förster Resonance Energy Transfer via Customized Ligands and Spatial Control of Donor–Acceptor Assembly
Understanding how to controllably modulate the efficiency of energy transfer in Förster resonance energy transfer (FRET)-based assemblies is critical to their implementation as sensing modalities. This is particularly true for sensing assemblies that are to be used as the basis for real time intracellular sensing of intracellular processes and events. We use a quantum dot (QD) donor -mCherry ac...
متن کاملAn Introduction to Fluorescence Resonance Energy Transfer (FRET) Technology and its Application in Bioscience
BioTek Instruments, Inc. P.O. Box 998, Highland Park, Winooski, Vermont 05404-0998 USA Phone: 888-451-5171 Outside the USA: 802-655-4740 Email: [email protected] www.biotek.com Copyright © 2012 Fluorescence Resonance Energy Transfer (FRET) is a physical phenomenon first described over 50 years ago, that is being used more and more in biomedical research and drug discovery today. FRET reli...
متن کاملA single-bead telomere sensor based on fluorescence resonance energy transfer.
We present a 200 nm in-diameter single-bead sensor for the detection of single, unlabeled DNA molecules in solution using fluorescence resonance energy transfer technology. DNA-bound Alexa 488 and Crimson 625 loaded on commercial beads served as the donor and acceptor, respectively. Binding of the target DNA to the single bead sensor induces G-quadruplex stretching, resulting in a decrease in f...
متن کاملFörster Resonance Energy Transfer between Quantum Dot Donors and Quantum Dot Acceptors
Förster (or fluorescence) resonance energy transfer amongst semiconductor quantum dots (QDs) is reviewed, with particular interest in biosensing applications. The unique optical properties of QDs provide certain advantages and also specific challenges with regards to sensor design, compared to other FRET systems. The brightness and photostability of QDs make them attractive for highly sensitive...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2001