Validation of the circular harmonic transform (CHT) algorithm for quantitative SPECT.
نویسندگان
چکیده
The purpose of this study was to validate the use of the circular harmonic transform (CHT) algorithm for quantitative single-photon emission computed tomography (SPECT) with isotopes technetium-99m (99mTc) and indium-111 (111In) under clinically relevant conditions. Phantom studies were the principal tools used. Volumes of fillable organs within a tissue-equivalent anthropomorphic phantom were determined over a wide range (145-1960 ml) to within 6% by using a thresholding technique. Additionally, phantom studies with nonuniform activity distributions were made. These included a background of activity and hot as well as cold lesions. The hot lesion was computed to within 12% (111In) and 7.7% (99mTc), and contrast in the cold lesion was approximately 70% for both isotopes. The CHT algorithm incorporates the energy-distance relation (EDR) which minimizes the degrading effects of attenuation, scatter, collimator blur and poor statistics.
منابع مشابه
Coin Recognition Using Circular Hough Transform
This paper represents algorithm for recognition of the coins of different denomination. The proposed system first uses a canny edge detection to generate an edge map, then uses CHT (Circular Hough transform) to recognize the coins and further find the radii of them. Based on the radius of the coin, the coins of different denomination are classified. The experimental result shows that the Hough ...
متن کاملFast Circle Detection Using Gradient Pair Vectors
The Circle Hough Transform (CHT) has become a common method for circle detection in numerous image processing applications. Because of its drawbacks, various modifications to the basic CHT method have been suggested. This paper presents an algorithm to find circles which are totally brighter or darker than their backgrounds. The method is size-invariant, and such circular shapes can be found ve...
متن کاملA Novel Approach for Coin Identification using Eigenvalues of Covariance Matrix, Hough Transform and Raster Scan Algorithms
In this paper we present a new method for coin identification. The proposed method adopts a hybrid scheme using Eigenvalues of covariance matrix, Circular Hough Transform (CHT) and Bresenham’s circle algorithm. The statistical and geometrical properties of the small and large Eigenvalues of the covariance matrix of a set of edge pixels over a connected region of support are explored for the pur...
متن کاملReversible Data Hiding in Images using Circular Hough Transform
Recently reversible data hiding (RDH) is getting more and more attention in encrypted images, as it maintains the excellent property that the original image cover can be losslessly recovered after the embedded data is extracted while image and data are protected and are confidential.This paper presents a method for reversible data hiding using circular hough transformation(CHT). CHT detects the...
متن کاملQuantitative SPECT and planar 32P bremsstrahlung imaging for dosimetry purpose –An experimental phantom study
Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 32 1 شماره
صفحات -
تاریخ انتشار 1991