Efficacy of new filter suction to decrease the rate of occlusion and total suction time in a simulated total hip replacement operation
نویسندگان
چکیده
BACKGROUND During orthopedic operations, such as total hip replacement or total knee replacement, there is a lot of bone debris from bone cutting and reaming that commonly causes surgical suction devices to occlude many times, which can prolong the operative time and increase the amount of bleeding for the patient. MATERIALS AND METHODS We developed a surgical filter suction system that we call the VY suction tube. The suction tube assembly consists of a tube filter within a housing assembly. The filter pore size was designed to prevent tissue or bone debris from passing through the filter, though it allows fluid to pass through. A simulated total hip replacement operation was performed to test the efficacy of this new suction device when compared with two other types of tube suction devices. RESULTS The VY suction tube showed that the mean duration to remove all fluid from a simulated field was significantly shorter than the Pool suction tube (P=0.0009) and Frazier suction tube (P=0.0012). The study also showed that the VY suction tube has a lower rate of occlusion when compared with the Pool suction tube (P≤0.0001) and Frazier suction tube (P≤0.0001). CONCLUSION Our new suction tube design shows good efficacy when removing fluid and debris from a simulated operative field. However, further studies in real clinical settings are needed.
منابع مشابه
An investigation into contamination of operative suction.
A study of the contamination of suckers used during total hip replacement has been undertaken. Thirty suckers used throughout the operation had their tips cultured: from 11 of these bacteria were grown. The organisms found were those which have previously been implicated in deep infection of total hip replacements. In subsequent operations a further 31 suckers were used for cleaning only the fe...
متن کاملThe Efficacy of Suction Drainage in Surgical Operations of Long Bone Fractures in Orthopedics
In this experimental trial , 133 patients with single long bone fracture requiring surgery, admitted in Shahid Mohammadi Hospital (Bandar Abbas/Iran) from June 2002 to April 2003, were randomly devided into two groups. In the first group (72 individuals), after the completion of the operation a single hemovac drain was inserted, while in the second group (61 patients) no drain was used. The two...
متن کاملThe effect of suction drains after total hip replacement.
A prospective study of 120 consecutive total hip replacements showed that deep suction drains produced maximal drainage volumes in the first 24 hours. Their continued presence resulted in minimal further drainage, did not reduce the likelihood of haematoma formation and led in some cases to the spread of skin organisms into the wound.
متن کاملSpinal and general anaesthesia in total hip replacement: frequency of deep vein thrombosis.
Subarachnoid block (SAB) or general anaesthesia (GA) was induced in 85 patients undergoing total hip replacement. The frequency of deep vein thrombosis (DVT), assessed by fibrinogen uptake studies and venography, was 29% in those patients receiving SAB and 54% in the GA group. Total blood loss (intra-operative and post-operative wound suction drainage) in SAB group was 66% and total transfusion...
متن کاملEffect of drain pressure in total knee arthroplasty.
PURPOSE To study the effect of drain suction pressure on drainage volume, decrease in haemoglobin level, blood transfusion, and wound complications following total knee arthroplasty. METHODS Primary total knee arthroplasty for degenerative osteoarthritis was performed in 60 (49 female and 11 male) patients. Patients were randomised for high-pressure (600 mm Hg) or low-pressure (350 mm Hg) pos...
متن کامل