Pressure stability with CPAP devices: A bench evaluation.

نویسندگان

  • Bruno Louis
  • Karl Leroux
  • Maud Boucherie
  • Daniel Isabey
  • Véronique Grillier-Lanoir
  • Brigitte Fauroux
  • Frédéric Lofaso
چکیده

BACKGROUND Continuous positive airway pressure (CPAP) maintains a constant pressure to reduce the patient's work of breathing (WOB). The aim of this study was to measure the additional WOB imposed by four current CPAP devices during simulation of a difficult but commonly encountered clinical situation. METHOD Flow contour, respiratory system compliance and total lung-airway resistance of a patient under CPAP were simulated. The devices were tested at a CPAP of 15cm H(2)O with a heated humidifier and a nasal pillow, which increased circuitry resistance and with and without a simulated unintentional leak. RESULTS With no leak, positive end-expiratory pressure (PEEP) at the interface varied across devices from 14.0 to 15.3cm H(2)O. With a leak of 1L/s, PEEP varied from 11.5 to 17.1cm H(2)O. Imposed inspiratory WOB ranged from less than 0.1J/min to 0.45J/min with no leak, and the range broadened with leaking. Findings were similar for the imposed expiratory WOB. CONCLUSION The performances of CPAP devices are variable. The device that calibrated for the pressure loss in the circuitry under dynamic conditions and made appropriate pressure adjustments outperformed the other devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Brief communication Pressure Stability with CPAP Devices: a Bench Evaluation

Background: Continuous positive airway pressure (CPAP) maintains a constant pressure to reduce the patient’s work of breathing (WOB). The aim of this study was to measure the additional WOB imposed by four current CPAP devices during simulation of a difficult, but commonly encountered, clinical situation. Method: A flow contour of a patient under CPAP and its respiratory mechanic were simulated...

متن کامل

CPAP Devices for Emergency Prehospital Use: A Bench Study.

BACKGROUND CPAP is frequently used in prehospital and emergency settings. An air-flow output minimum of 60 L/min and a constant positive pressure are 2 important features for a successful CPAP device. Unlike hospital CPAP devices, which require electricity, CPAP devices for ambulance use need only an oxygen source to function. The aim of the study was to evaluate and compare on a bench model th...

متن کامل

Imposed Work of Breathing for Flow Meters with In-Line versus Flow-Through Technique during Simulated Neonatal Breathing

BACKGROUND The ability to determine airflow during nasal CPAP (NCPAP) treatment without adding dead space or resistance would be useful when investigating the physiologic effects of different NCPAP systems on breathing. The aim of this study was to investigate the effect on pressure stability of different flow measuring devices at the in-line and flow-through position, using simulated neonatal ...

متن کامل

Nasal continuous positive airway pressure (CPAP) for the respiratory care of the newborn infant.

Nasal continuous positive airway pressure (CPAP) is a noninvasive form of respiratory assistance that has been used to support spontaneously breathing infants with lung disease for nearly 40 years. Following reports that mechanical ventilation contributes to pulmonary growth arrest and the development of chronic lung disease, there is a renewed interest in using CPAP as the prevailing method fo...

متن کامل

Control system design for a continuous positive airway pressure ventilator

Continuous Positive Airway Pressure (CPAP) ventilation remains a mainstay treatment for obstructive sleep apnea syndrome (OSAS). Good pressure stability and pressure reduction during exhalation are of major importance to ensure clinical efficacy and comfort of CPAP therapy. In this study an experimental CPAP ventilator was constructed using an application-specific CPAP blower/motor assembly and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Sleep medicine

دوره 11 1  شماره 

صفحات  -

تاریخ انتشار 2010