Stroke Volume Variation for Prediction of Fluid Responsiveness in Patients Undergoing Gastrointestinal Surgery
نویسندگان
چکیده
BACKGROUND Stroke volume variation (SVV) has been shown to be a reliable predictor of fluid responsiveness. However, the predictive role of SVV measured by FloTrac/Vigileo system in prediction of fluid responsiveness was unproven in patients undergoing ventilation with low tidal volume. METHODS Fifty patients undergoing elective gastrointestinal surgery were randomly divided into two groups: Group C [n(1)=20, tidal volume (V(t)) = 8 ml/kg, frequency (F) = 12/min] and Group L [n(2)=30, V(t)= 6 ml/kg, F=16/min]. After anesthesia induction, 6% hydroxyethyl starch130/0.4 solution (7 ml/kg) was intravenously transfused. Besides standard haemodynamic monitoring, SVV, cardiac output, cardiac index (CI), stroke volume (SV), stroke volume index (SVI), systemic vascular resistance (SVR) and systemic vascular resistance index (SVRI) were determined with the FloTrac/Vigileo system before and after fluid loading. RESULTS After fluid loading, the MAP, CVP, SVI and CI increased significantly, whereas the SVV and SVR decreased markedly in both groups. SVI was significantly correlated to the SVV, CVP but not the HR, MAP and SVR. SVI was significantly correlated to the SVV before fluid loading (Group C: r = 0.909; Group L: r = 0.758) but not the HR, MAP, CVP and SVR before fluid loading. The largest area under the ROC curve (AUC) was found for SVV (Group C, 0.852; Group L, 0.814), and the AUC for other preloading indices in two groups ranged from 0.324 to 0.460. CONCLUSION SVV measured by FloTrac/Vigileo system can predict fluid responsiveness in patients undergoing ventilation with low tidal volumes during gastrointestinal surgery.
منابع مشابه
Dynamic preload markers to predict fluid responsiveness during and after major gastrointestinal surgery: an observational substudy of the OPTIMISE trial.
BACKGROUND Stroke volume variation (SVV) and pulse pressure variation (PPV), termed dynamic markers of preload responsiveness, may predict the response to i.v. fluid in critically ill patients. However, the predictive accuracy of these variables during gastrointestinal surgery remains uncertain. METHODS Observational study of patients aged ≥50 yr undergoing major gastrointestinal surgery, enr...
متن کاملPrediction of fluid responsiveness using a non-invasive cardiac output monitor in children undergoing cardiac surgery.
BACKGROUND This study evaluated the ability of a non-invasive cardiac output monitoring device (NICOM) to predict fluid responsiveness in paediatric patients undergoing cardiac surgery. METHODS Children aged <5 yr undergoing congenital heart surgery were included. Once the sternum had been closed after repair of the congenital heart defect, 10 ml kg(-1) colloid solution was administered for v...
متن کاملPulse pressure variation and stroke volume variation to predict fluid responsiveness in patients undergoing carotid endarterectomy
BACKGROUND During carotid endarterectomy (CEA), hemodynamic stability and adequate fluid management are crucial to prevent perioperative cerebral stroke, myocardial infarction and hyperperfusion syndrome. Both pulse pressure variation (PPV) and stroke volume variation (SVV), dynamic preload indices derived from the arterial waveform, are increasingly advocated as predictors of fluid responsiven...
متن کاملEvaluation of stroke volume variation obtained by arterial pulse contour analysis to predict fluid responsiveness intraoperatively.
BACKGROUND Fluid management guided by oesophageal Doppler monitor has been reported to improve perioperative outcome. Stroke volume variation (SVV) is considered a reliable clinical predictor of fluid responsiveness. Consequently, the aim of the present trial was to evaluate the accuracy of SVV determined by arterial pulse contour (APCO) analysis, using the FloTrac/Vigileo system, to predict fl...
متن کاملAutomated pulse pressure and stroke volume variations from radial artery: evaluation during major abdominal surgery.
BACKGROUND Off-line calculation of the pulse pressure variation (PPV(ref)) has repeatedly been shown to be a reliable predictor of fluid responsiveness in mechanically ventilated patients. This study was designed to assess the ability of two algorithms for automated calculation of PPV (PPV(auto)) (Intellivue MP 70) and stroke volume variation (SVV(auto)) (FloTrac/Vigileo) to predict fluid respo...
متن کامل