Success Rate and Time for Bypassing the Fractured Segments of Four NiTi Rotary Instruments

نویسندگان

  • Alireza Adl
  • Arash Shahravan
  • Melika Farshad
  • Shahab Honar
چکیده

INTRODUCTION The aim of this in vitro study was to compare the success rate and time required for bypassing the fractured segments of four different nickel-titanium (NiTi) rotary systems. METHODS AND MATERIALS This study was conducted on the mesiobuccal canals of 60 mandibular molars with fully-formed apices. Fifteen Flex Master, K3, RaCe and Hero Shaper instruments with 0.04 taper and tip size of #30 and 25 mm in length, were obtained. These instruments were notched at a point 3 mm from the tip of the instrument and were driven into the canals using a handpiece until the instruments fractured and became lodged therein. In the next step, an endodontist tried to bypass the fractured segment using K-files. The number of bypassed samples and the time required for bypassing of each sample were recorded. The Chi-square test was used to compare the bypassing rate among the experimental groups. One-way analysis of variance followed by Tukey's post hoc test was conducted to compare the time taken for bypassing of the fractured fragments. RESULTS One instrument in Flex Master group and two broken segments in each of the K3 and Hero groups were not bypassed. All of the samples in RaCe group were bypassed. No significant difference was found among four tested groups regarding rate of bypassing (P=0.738). The time taken to bypass fragments in the Hero group was significantly more than in those of K3 (P=0.047) and RaCe (P=0.024). CONCLUSION Under the limitations of this study, design features of rotary files can influence the time needed to bypass separated fragments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tips to avoid instrument separation in endodontics.

procedural accidents and obstacles to normally routine therapy, at almost any stage of treatment. One of these procedural problems is intracanal instrument fracture. Fractured root canal instruments may include endodontic files (Figure 1) and Gates Glidden burs. Instruments are made from nickel titanium (NiTi), stainless steel or carbon steel. Fracture often results from incorrect use or overus...

متن کامل

PathFiles: A New Rotary Nickel-Titanium Instrument for Mechanical Glide Path and Preflaring

NiTi instrument separation is a serious concern in endodontic therapy. The analysis of NiTi files after torsional fracture reveals that the majority of torsional separations occur in the last mm. of the files and in the files with lower taper and/ or diameter. Consequentely, the tip of the smaller files presents the higher risk of torsional fracture and should be protected using low torque moto...

متن کامل

PathFileTM: A New Rotary Nickel-Titanium Instrument for Mechanical Glide Path and Preflaring

NiTi instrument separation is a serious concern in endodontic therapy. The analysis of NiTi files after torsional fracture reveals that the majority of torsional separations occur in the last mm. of the files and in the files with lower taper and/ or diameter. Consequentely, the tip of the smaller files presents the higher risk of torsional fracture and should be protected using low torque moto...

متن کامل

Application of nondestructive testing in cyclic fatigue evaluation of endodontic Ni-Ti rotary instruments.

The purpose of this study was to investigate the application of nondestructive testing in cyclic fatigue evaluation of endodontic ProFile nickel-titanium (NiTi) rotary instruments. As-received ProFile instruments were made to rotate freely in sloped metal blocks by a contra-angle handpiece mounted on a testing machine. Rotation was interrupted periodically, and the instrument removed and engage...

متن کامل

Sterilization of rotary NiTi instruments within endodontic sponges.

AIM To determine whether the following can be sterilized by autoclaving - endodontic sponges, rotary nickel-titanium (NiTi) instruments within endodontic sponges, and rotary NiTi instruments with rubber stoppers. METHODOLOGY Sixty-four samples of eight different endodontic sponges (n = 512) were placed into brain heart infusion broth (BHI) for 72 h. An aliquot of this was then spread onto hor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017