Improved clearance of iohexol with longer haemodialysis despite similar Kt/V for urea.

نویسندگان

  • E Johnsson
  • P O Attman
  • O Samuelsson
  • B Haraldsson
چکیده

BACKGROUND The efforts to improve the quality of haemodialysis (HD) has renewed the interest in the consequences of blood-flow distribution for removal of solutes. METHODS To test the effects of HD time per se, 10 patients were studied in a cross-over fashion with HD for 3 h and 1 week later for 6 h, with similar blood urea Kt/Vs, achieved by adjusting the blood flow rate to 290 and 120 ml/min respectively. Injections of iohexol (MW 821 Dalton) were given 2 days prior to the dialysis sessions. Blood samples were taken before, during (6/HD), 1 and 24 h after the HD and analysed for concentrations of urea and iohexol. A urea on-line monitor (Gambro) was used for continuous recordings and sampling of dialysate. RESULTS According to the study design the blood Kt/V for urea (Daugirdas II) was similar for 3 and 6 h HD, close to 1.0 (n.s), while the removed mass of urea showed that Kt/V was slightly and significantly higher for the 6 h HD. The 'apparent' mass of iohexol, defined as plasma concentration times estimated distribution volume, fell to 29% and 21% of pre-dialysis levels after 3 h and 6 h HD, respectively (P<0.01), but increased after HD, and more so after the short dialysis, reaching 46% of the predialysis mass 24 h after 3 h HD vs. 36% after 6 h HD (P<0.05). The removed mass of iohexol was 920+/-110 mg with 6h HD and 700+/-81 mg with 3h HD, (P<0.01). Thus, the longer dialysis removed 32% more iohexol despite similar blood Kt/V for urea. CONCLUSION The treatment time per se affects solute removal despite similar blood Kt/V for urea. This is particularly true for an intermediate-size molecule like iohexol.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dialysis dose (Kt/V) and clearance variation sensitivity using measurement of ultraviolet-absorbance (on-line), blood urea, dialysate urea and ionic dialysance.

BACKGROUND An on-line monitoring system for dialysis dose calculations could make it possible to provide an adequate dialysis dose that is consistently given to haemodialysis (HD) patients. The aim of this study was to compare dialysis dose (Kt/V) using four different methods and their sensitiveness to a reduction in clearance. METHODS Six patients were monitored on-line with ultraviolet (UV)...

متن کامل

A comparison of methods for determining urea distribution volume for routine use in on-line monitoring of haemodialysis adequacy.

BACKGROUND The availability of haemodialysis machines equipped with on-line clearance monitoring (OCM) allows frequent assessment of dialysis efficiency and adequacy without the need for blood samples. Accurate estimation of the urea distribution volume 'V' is required for Kt/V calculated from OCM to be consistent with conventional blood sample-based methods. METHODS Ten stable HD patients we...

متن کامل

Do we need another Kt/V?

A new method of estimating Kt/V has been proposed. This was a required update to accommodate frequencies of dialysis other than thrice weekly [1].The original approximate method for calculating Kt/V from preand post-dialysis urea concentrations was developed using linear regression on a data set of measurements taken from patients undergoing thrice-weekly dialysis. The method assumes that the i...

متن کامل

Kinetics and dosing predictions for daily haemofiltration.

BACKGROUND Thrice-weekly haemofiltration affords excellent outcome when it is used to treat chronic renal failure patients. Daily haemofiltration (DHF) has recently been proposed as a more intensive therapy option, but the total ultrafiltration or exchange volume (replacement volume plus net ultrafiltration volume) requirements for adequate solute clearances during this novel therapy are unknow...

متن کامل

Effect of treatment spacing and frequency on three measures of equivalent clearance, including standard Kt/V.

BACKGROUND We examined the sensitivity of three different equivalent clearances to the spacing of haemodialysis treatments as well as to frequency. One would expect that a well-spaced schedule would be beneficial, and an optimal clearance measure should reflect this. METHODS Using a variable volume two-pool urea kinetic model, we derived clearances based on G [urea nitrogen (UN) generation ra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 14 10  شماره 

صفحات  -

تاریخ انتشار 1999