Relative biological effectiveness of therapeutic proton beams for HSG cells at Japanese proton therapy facilities

نویسندگان

  • Mizuho Aoki-Nakano
  • Yoshiya Furusawa
  • Akiko Uzawa
  • Yoshitaka Matsumoto
  • Ryoichi Hirayama
  • Chizuru Tsuruoka
  • Takashi Ogino
  • Teiji Nishio
  • Kazufumi Kagawa
  • Masao Murakami
  • Go Kagiya
  • Kyo Kume
  • Masanori Hatashita
  • Shigekazu Fukuda
  • Kazutaka Yamamoto
  • Hiroshi Fuji
  • Shigeyuki Murayama
  • Masaharu Hata
  • Takeji Sakae
  • Hideki Matsumoto
چکیده

We investigated the relative biological effectiveness (RBE) of therapeutic proton beams at six proton facilities in Japan with respect to cell lethality of HSG cells. The RBE of treatments could be determined from experimental data. For this purpose, we used a cell survival assay to compare the cell-killing efficiency of proton beams. Among the five linear accelerator (LINAC) X-ray machines at 4 or 6 MeV that were used as reference beams, there was only a small variation (coefficient of variation CV = 3.1% at D10) in biological effectiveness. The averaged value of D10 for the proton beams at the middle position of the spread-out Bragg peak (SOBP) was 4.98. These values showed good agreement, with a CV of 4.3% among the facilities. Thus, the average RBE10 (RBE at the D10 level) at the middle position of the SOBP beam for six facilities in Japan was 1.05 with a CV of 2.8%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Erratum to ‘Microdosimetric calculation of relative biological effectiveness for design of therapeutic proton beams’†

The authors attempt to establish the relative biological effectiveness (RBE) calculation for designing therapeutic proton beams on the basis of microdosimetry. The tissue-equivalent proportional counter (TEPC) was used to measure microdosimetric lineal energy spectra for proton beams at various depths in a water phantom. An RBE-weighted absorbed dose is defined as an absorbed dose multiplied by...

متن کامل

Analysis of Relative Biological Effectiveness of Proton Beams and Iso-effective Dose Profiles Using Geant4

Background: The assessment of RBE quantity in the treatment of cancer tumors with proton beams in treatment planning systems (TPS) is of high significance. Given the significance of the issue and the studies conducted in the literature, this quantity is fixed and is taken as equal to 1.1.Objective: The main objective of this study was to assess RBE quantity of proton beams and their variations ...

متن کامل

Evaluation of variable relative biological effectiveness and the creation of homogenous biological dose in the tumor region in helium ion radiation to the V79 cell line

In radiation therapy, ions heavier than proton have more biological advantages than a proton beam. Recently, ion helium has been considered due to high linear energy transfer (LET) to the medium and a higher relative biological effect (RBE). To design the spread-out Bragg peak (SOBP) of biological dose for radiation with any type of ion, we need exact values of RBE, which is dependent to dose, ...

متن کامل

RBE and OER within the spread-out Bragg peak for proton beam therapy: in vitro study at the Proton Medical Research Center at the University of Tsukuba

There are few reports on the biological homogeneity within the spread-out Bragg peak (SOBP) of proton beams. Therefore, to evaluate the relative biological effectiveness (RBE) and the oxygen enhancement ratio (OER), human salivary gland tumor (HSG) cells were irradiated at the plateau position (position A) and three different positions within a 6-cm-wide SOBP (position B, 26 mm proximal to the ...

متن کامل

Dose estimation with the calibration of dose-response curve of micronucleus in human peripheral lymphocytes induced by 50MeV proton beams

Background: The purpose of this paper is to establish an easy and reliable biodosimeter protocol to evaluate the biological effects of proton beams. Materials and Methods: Human peripheral blood lymphocytes were irradiated using proton beams (LET: 34.6 keV μm−1), and the chromosome aberrations induced were analyzed using cytokinesis-blocked (CB) micronucleus (MN) assay. To determine th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 55  شماره 

صفحات  -

تاریخ انتشار 2014