Adaptation of Babson's Method for the Determination of Serum Glutamic Oxalacetic Transaminase in the Clinical Laboratory.

نویسندگان

  • M FURUNO
  • A SHEENA
چکیده

E NEED for an accurate and simple determination for serum glutamic oxalacetic transaminase (SGO-T) in the clinical laboratory led! us to investigate a procedure published recelltiy by Babson et al. (1,2). III this niethod the (hiazonium salt, (i-bellzamido-4-methoxv-ln-tolui(line (liazoluunl chloride, pro(111c’s a higilly specific color for the oxalacetic acid! fornied as a product of transamination. rllhe procedure is not well suited for tile routine laboratory without the use of costly automatic, devices, since the filial color formed is unstable 1111(1 increases with time. Our present work introduces tile use of sodium metabisulfite to i)i oduce a stable filial color, and presents further lno(hifications to increase accuracy. Reagents and Materials

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated Determination of Serum Glutamic Oxalacetic and Glutamic Pyruvic Transaminase.

The determination of serum glutamic oxalacetic and glutamic pyruvic transaminase has been simplified by the use of automated analysis. The flow diagrams, concentration of reagents, and calculation of the color unit in terms of the Karmen unit are shown for 2,4-dinitrophenylhydrazine and 6-benzamido-4-methoxy-m -toluidine diazonium chloride as the reacting dyes. Advantages of both methods are co...

متن کامل

Electrophoresis of Glutamic Oxalacetic Transaminase in Serum, Beef Heart, and Liver Homogenates on Cellulose Acetate.

‘THE RECENT DEVELOPMENT of a new colorimetric procedure (TransAc*), for the determination of serum glutamic oxalacetic transaminase utilizing the diazonium salt, 6-benzamido-4-methoxy-m-toluidine diazonium chloride, as the color developer with a specificity for oxalacetic acid, prompted the following experiments. Determination of glutamic oxalacetic transaminase activities were performed accord...

متن کامل

Serum glutamic oxalacetic transaminase assay using the sequential multiple analyzer (SMA 12-30).

The SMA-12/30 method for serum glutamic oxalacetic transaminase assay gives higher values than are obtained with a reference spectrophotometric method for someserums.A modification of the manifold is made to permit the running of serum blanks. Blank corrections on 466 serum samples indicate that dialysis does not eliminate the need for the blank determination. Acetoacetate interferes in the SMA...

متن کامل

Determination of glutamic oxalacetic transaminase activity by coupling of oxalacetate with diazonium salts.

A method for measuring serum glutamic oxalacetic transaminase activity is described, in which substrate concentrations are more nearly optimal than in previous colonmetric methods. By coupling the diazonium salt at a pH of 4.2, interference from a-oxoglutarate is negligible. Oxalacetate is produced at a linear rate to 180 l.U. Results correlate well with those obtained by a reference spectropho...

متن کامل

Technical improvements in measurement of L -aspartate:2-oxoglutarate aminotransferase activity in serum by diazonium salt coupling.

3. Jacobs, W. L. W., Gamrna-glutamyl transpeptidase in disease of the liver, cardiovascularsystem and diabetesmellitus.Clin. Chim. Acta 38,419(1972). 4. Karmen, A., A note on the spectrophotometric assay of glutamic oxalacetic transaminase in human blood serum. J. Clin. Invest. 34, 131 (1955). 5. Wroblewski, F., and La Due, J. S., Serum glutamic pyruvic transaminase in cardiac and hepatic disea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 11  شماره 

صفحات  -

تاریخ انتشار 1965