A differentiable Shepp-Logan phantom and its applications in exact cone-beam CT.

نویسندگان

  • Hengyong Yu
  • Shiying Zhao
  • Ge Wang
چکیده

Recently, several exact cone-beam reconstruction algorithms, such as the generalized filtered-backprojection (FBP) and backprojection-filtration (BPF) methods, have been developed to solve the long object problem. Although the well-known 3D Shepp-Logan phantom (SLP) is often used to validate these algorithms, it is deficient due to the discontinuity of the SLP. In this paper, we first construct a differentiable polynomial function to approximate the unit rectangular function on [-1, 1]. Then, we use this function to obtain a differentiable ellipsoid phantom, whose x-ray transform is differentiable for any smooth scanning trajectory. Finally, we propose a differentiable Shepp-Logan phantom (DSLP) for numerical simulation of the exact cone-beam CT algorithms. Our numerical simulation shows that the reconstructed DSLP has a better image quality than the reconstructed SLP, and is complementary to the traditional SLP for evaluation of the exact cone-beam CT algorithms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cone-beam pseudo-lambda tomography

Abstract In this paper, for the first time we define the concept of 3D pseudo-lambda tomography based on the 3D Calderon operator, and formulate an approximate local reconstruction algorithm for cone-beam data collected along an arbitrary scanning curve. The main idea is to rewrite the filtering operator in an exact filtered-backprojection reconstruction formula as a local projection. Simulatio...

متن کامل

A backprojection-filtration algorithm for nonstandard spiral cone-beam CT with an n-PI-window.

For applications in bolus-chasing computed tomography (CT) angiography and electron-beam micro-CT, the backprojection-filtration (BPF) formula developed by Zou and Pan was recently generalized by Ye et al to reconstruct images from cone-beam data collected along a rather flexible scanning locus, including a nonstandard spiral. A major implication of the generalized BPF formula is that it can be...

متن کامل

Half-scan cone-beam CT fluoroscopy with multiple x-ray sources.

To develop volumetric micro-CT fluoroscopy for small animal imaging, we have proposed a cone-beam system with multiple x-ray sources. In this paper, we extend Parker's single-source half-scan weighting scheme to the case of an odd number of x-ray sources that are equiangularly distributed, and apply it for half-scan Feldkamp-type reconstruction in this unique geometry. In the numerical simulati...

متن کامل

X-ray micro-CT with a displaced detector array.

Because the sizes of samples differ in x-ray micro-CT applications, it is desirable to have a mechanism to change the field of view of a micro-CT scanner. A well-known way to double the diameter of the field of view is to displace a detector array by 50%. In this paper, we propose to displace a detector array by an amount of greater than 0% but less than 50% for a continuously adjustable field ...

متن کامل

Helical CT Reconstruction from Wide Cone-Beam Angle Data Using ART

We report on new results on the use of Algebraic Reconstruction Techniques (ART) for reconstructing from helical cone-beam Computerized Tomography (CT) data. We investigate two variants of ART for this task: a standard one that considers a single ray in an iterative step and a block version which groups several cone-beam projections when calculating an iterative step. Both algorithms were imple...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 50 23  شماره 

صفحات  -

تاریخ انتشار 2005