This will be a discussion of the non-invasive determination of the viscosity of a non-Newtonian fluid in laminar pipe flow over the range of shear rates present in the pipe. The procedure used requires knowledge of the flow profile in and the pressure drop along a long straight run of pipe. The profile is determined by using a pulsed ultrasonic Doppler velocimeter. This approach is ideal for making non-invasive, real-time measurements for monitoring and control. Rheograms of a shear thinning gel will be presented. The operating parameters and limitations of the Doppler-based instrument will be discussed. The most significant limitation is velocity gradient broadening of the Doppler spectra near the walls of the pipe. This limitation can be significant for strongly shear thinning fluids (depending also on the ratio of beam to pipe diameter and the transducer's insertion angle).
منابع مشابه
Regional blood flow measurement with pulsed Doppler flowmeter in conscious rat.
Development of techniques for the continuous measurement of regional blood flow and vascular resistance in intact small animals has been impeded primarily by the bulkiness of flow probes. The availability of an ultrasonic pulsed Doppler flowmeter system enabled us to construct miniaturized probes using 1-mm-diameter piezoelectric crystals that emit a 20-mHz signal and receive the reflected soun...
متن کاملLocalisation and direction of mitral regurgitant flow in mitral orifice studied with combined use of ultrasonic pulsed Doppler technique and two dimensional echocardiography.
Regurgitant flow was analysed in 40 cases of mitral regurgitation, using combined ultrasonic pulsed Doppler technique and two dimensional echocardiography. Abnormal Doppler signals indicative of mitral regurgitant flow were detected in reference to the two dimensional image of the long axis view of the heart and the short axis view at the level of the mitral orifice. The overall direction of re...
متن کاملUltrasonic demonstration of external and internal carotid patency with common carotid occlusion: a preliminary report.
Non-invasive ultrasonic imaging of the carotid bifurcation by duplex scanning and ultrasonic arteriography combined with pulsed Doppler spectrum analysis demonstrated patency of the external and internal carotid arteries distal to a common carotid occlusion in 3 patients. Common carotid occlusion is not invariably associated with thrombosis of the ipsilateral internal carotid artery. Identifica...
متن کاملNormal left ventricular systolic time intervals assessed by pulsed wave Doppler echocardiography in the Turkmen horse of Iran
The Turkmen horse is one of the oldest and purest breeds in the world. There is no information with regards to the normal echocardiographic parameters of this horse regarding to cardiac diseases. Pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. There were 26 stallions and 16 mares. The left ventricular isovolumetric contrac...
متن کاملEvaluation of tricuspid regurgitation by pulsed Doppler and two-dimensional echocardiography.
We analyzed tricuspid regurgitation noninvasively using ultrasonic pulsed Doppler and two-dimensional echocardiography in 66 patients in whom tricuspid regurgitation was suspected from routine clinical evaluation. All of the patients also underwent right ventriculography. Ten healthy subjects served as controls. In 62 of 66 patients, the study was adequately performed. In 58 of 62 patients, pan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultrasonics
دوره 44 Suppl 1 شماره
صفحات -
تاریخ انتشار 2006