Contact Lenses for Keratoconus- Current Practice

نویسندگان

  • Marilita M. Moschos
  • Eirini Nitoda
  • Panagiotis Georgoudis
  • Miltos Balidis
  • Eleftherios Karageorgiadis
  • Nikos Kozeis
چکیده

BACKGROUND Keratoconus is a chronic, bilateral, usuallly asymmetrical, non-inflammatory, ectatic disorder, being characterized by progressive steepening, thinning and apical scarring of the cornea. Initially, the patient is asymptomatic, but the visual acuity gradually decreases, resulting in significant vision loss due to the development of irregular astigmatism, myopia, corneal thinning and scarring. The classic treatment of visual rehabilitation in keratoconus is based on spectacles and contact lenses (CLs). OBJECTIVE To summarize the types of CLs used in the treatment of keratoconus. This is literature review of several important published articles focusing on the visual rehabilitation in keratoconus with CLs. METHOD Gas permeable (GP) CLs have been found to achieve better best corrected visual acuity than spectacles, eliminating 3rd-order coma root-mean-square (RMS) error, 3rd-order RMS, and higher-order RMS. However, they have implicated in reduction of corneal basal epithelial cell and anterior stromal keratocyte densities. Soft CLs seem to provide greater comfort and lower cost, but the low oxygen permeability (if the lens is not a silicone hydrogel), and the inability to mask moderate to severe irregular astigmatism are the main disadvantages of them. On the other hand, scleral CLs ensure stable platforms, which eliminate high-order aberrations and provide good centration and visual acuity. Their main disadvantages include the difficulties in application and removal of these lenses along with corneal flattening and swelling. RESULT The modern hybrid CLs are indicated in cases of poor centration, poor stability or intolerance with GP lenses. Finally, piggyback CL systems effectively ameliorate visual acuity, but they have been related to corneal neovascularization and giant papillary conjunctivitis. CONCLUSION CLs seem to rehabilitate visual performance, diminishing the power of the cylinder and the high-order aberrations. The final choice of CLs is based on their special features, the subsequent corneal changes and the patient's needs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nonsurgical Procedures for Keratoconus Management

Objectives To describe the past 20 years' correction modalities for keratoconus and their visual outcomes and possible complications. Methods A review of the published literature related to the visual outcomes and possible complications in the context of keratoconus management using nonsurgical procedures for the last 20 years (glasses and contact lenses) was performed. Original articles that...

متن کامل

Contact lenses fitting after intracorneal ring segments implantation in keratoconus.

PURPOSE Evaluate contact lenses fitting after intracorneal ring implantation for keratoconus, its visual acuity and comfort. METHODS Retrospective study of patients undergoing contact lenses fitting, after intracorneal ring for keratoconus. The criterion for contact lens fitting was unsatisfactory visual acuity with spectacle correction as referred by the patients. All patients were intoleran...

متن کامل

Contact lenses as the best conservative treatment of newly diagnosed keratoconus--epidemiological retrospective study.

Keratoconus is a progressive, non-inflammatory corneal ectasia characterized by thinning and weakening of the corneal stroma which results in its' protrusion. The onset is during puberty and progresses until the fourth decade of life. In earlier stages, good visual acuity can be provided with spectacles. With progression, contact lenses are considered to be a better therapy. Aim of this study w...

متن کامل

Success of hydrocone (TORIS-K) soft contact lens for keratoconus and traumatic keratopathy

OBJECTIVE To present success of Toris-K contact lenses in keratoconus and traumatic keratopathy with irregular corneal surface. METHODS Toris-K contact lenses were used to treat 7 eyes of 4 patients with traumatic keratopathy (Case 1) or keratoconus (Case 2, Case 3, and Case 4). All cases had a complete eye examination before the contact lens application. The case with traumatic keratopathy w...

متن کامل

Descriptive analysis of the type and design of contact lenses fitted according to keratoconus severity and morphology.

PURPOSE Keratoconus is characterized by bilateral asymmetrical corneal ectasia that leads to inferior stromal thinning and corneal protrusion. There is currently a lack of consensus regarding the most efficacious method for fitting contact lenses in patients with keratoconus, given the various topographical patterns and evolution grades observed in affected populations. The purpose of the prese...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2017