BACKGROUND AND PURPOSE Time-resolved MRA imaging is a promising technique for blood flow evaluation in case of cerebrovascular malformations. Unfortunately, 4D MRA imaging is a trade-off between spatial and temporal resolution. The aim of this study was to investigate the influence of temporal resolution on the error associated with TTP estimation from indicator dilution curves derived from different vascular structures. MATERIALS AND METHODS Monte Carlo simulation was performed to compute indicator dilution curves with known criterion standard TTP at temporal resolutions between 0.1 and 5 seconds. TTPs were estimated directly and by using 4 hemodynamic models for each curve and were compared with criterion standard TTP. Furthermore, clinical evaluation was performed by using 226 indicator dilution curves from different vessel structures obtained from clinical datasets. The temporal resolution was artificially decreased, and TTPs were estimated and compared with those obtained at the original temporal resolutions. The results of the clinical evaluations were further stratified for different vessel structures. RESULTS The results of both evaluations show that the TTP estimation error increases exponentially when one lowers the temporal resolution. TTP estimation by using hemodynamic model curves leads to lower estimation errors compared with direct estimation. A temporal resolution of 1.5 seconds for arteries and 2.5 seconds for venous and arteriovenous malformation vessel structures appears to be reasonable to achieve TTP estimations adequate for clinical application. CONCLUSIONS Different vessel structures require different temporal resolutions to enable comparable TTP estimation errors, which should be considered for achieving a case-optimal temporal and spatial resolution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Visualization and Analysis of Cerebral Arteriovenous Malformation combining 3D and 4D MR Image Sequences

In this paper methods for visualization and analysis of cerebral arteriovenous malformations (AVM) are presented. Spatiotemporal 4D magnetic resonance angiography (MRA) image datasets and 3D MRA datasets with high spatial resolution were acquired for analyzing AVMs. One of the main tasks is the combination of the information of these 3D and 4D MRA image sequences. Initially, in the 3D MRA datas...

متن کامل

طراحی پروتکل MR انژیوگرافی اندام تحتانی با استفاده از دستگاه 1.5MRI تسلا

Background and purpose: Ôn time diagnosis and treatment of lower limb diseases are of crucial importance to the patients. Çonventional angiography is the standard procedure of diagnosis, which is followed by different problems such as, X-ray hazards, sensitivity to contrast drugs and complications of opening vessel. Doppler ultrasonography has low differentiation power. MR angiography is a s...

متن کامل

Ferumoxytole-enhanced 4D MR angiography with retrospectively defined temporal resolution

Background In cardiovascular MRI applications, high spatial resolution is preferable for anatomical evaluation of vascular structures and high temporal resolution is desired in cardiac functional assessment. As a result, current CMR protocol usually includes repeated scans of the same anatomy with different resolution settings. To address this issue, we propose a technique that allows for retro...

متن کامل

4D time-resolved MR angiography with keyhole (4D-TRAK): more than 60 times accelerated MRA using a combination of CENTRA, keyhole, and SENSE at 3.0T.

PURPOSE To present a new 4D method that is designed to provide high spatial resolution MR angiograms at subsecond temporal resolution by combining different techniques of view sharing with parallel imaging at 3.0T. MATERIALS AND METHODS In the keyhole-based method, a central elliptical cylinder in k-space is repeated n times (keyhole) with a random acquisition (CENTRA), and followed by the re...

متن کامل

تعیین مناسب‌ترین روش برآورد رسوب معلق بر اساس آماره‌های خطاسنجی (مطالعه موردی-تعدادی از زیرحوزه‌های کشف‌رود)

The phenomena of erosion, sediment transport and sedimentations have tremendously destructive effects on environment and hydraulics structures. In general, sediment transportation depends on river discharges, but the proposed equations inherited with large errors. To evaluate the suspended sediment loads and an optimized model on them, in this research, data were collected from some sub-watersh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 33 11  شماره 

صفحات  -

تاریخ انتشار 2012