Measurement of surface alpha contamination using electret ion chambers.

نویسندگان

  • S K Dua
  • S K Biswas
  • P Szerszen
  • J Boudreaux
  • M A Ebadian
چکیده

Electret ion chambers are inexpensive, light-weight, commercially available, passive charge-integrating devices for accurate measurement of different radiations. Performance of electret ion chambers for surface alpha contamination measurement was evaluated. Ion chambers of two types and electrets of three thicknesses were used for the study. Calibration of the electret ion chambers was performed using reference alpha standards of different energies and radioactivities. Effects of various parameters such as chamber dimensions, electret thickness, alpha particle energy, position of alpha source from the chamber centerline, source localized or uniformly distributed, level of alpha contamination, Mylar window covering the chamber, and ambient radon and gamma radiation on the response of the electret ion chambers were determined. Suitable combinations of chambers and electrets to measure surface alpha contamination were determined.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Alternate Performance Standard Project - Interpreting the Post - Construction Test

In support of a possible performance standard for radon-resistant construction for the State of Florida, a protocol is needed to provide postconstruction indoor radon measurement. In order to relate the results of short term compliance measurements to inferred annual average concentrations, a study was conducted in four regions of Florida known to have potential for elevated indoor radon. Eight...

متن کامل

Effective Point of Measurement in Cylindrical Ion Chamber for Megavoltage Photon Beams

Introduction For dose measurement in Megavoltage (MV) photon beams with ion chambers, the effect of volume occupied by the air cavity is not negligible. Therefore, the result of measurement should be corrected with a displacement perturbation correction factor (Pdis) or using an effective point of measurement (EPOM). The aim of this study is to calculate the EPOM for cylindrical ion chamber and...

متن کامل

Conceptual Design and Simulation of Alpha-Beta Detector for Surface Contamination Measurements

The radioactive contamination measurement is essential in nuclear facilities. Monitoring of low level alpha and beta contamination is possible using light detectors high efficiency. Due to the fact that many detectors canchr('39')t simultaneously discriminate alpha, beta and gamma rays; among existing methods, phoswich detectors would be appropriate option to measure different radioactive conta...

متن کامل

Elevation Correction Factors K)r E-perm(r) Radon Monitors

E-PERM(R) radon monitors are based on the principle of electret ion chambers and these are usually calibrated in a standard radon chamber located at sea level. Corrections are needed if these are used in elevations other than sea level. These were experimentally determined for three models of commercially available electret ion chambers (E-PERMS(R)) as functions of elevation above sea level. . ...

متن کامل

Electret ion chamber-based passive radon-thoron discriminative monitors.

Electret ion chambers (EICs), commercially available under brand name E-PERM(®), are widely used for measuring indoor and outdoor (222)Rn concentrations in air. These are designed to respond only to (222)Rn and not to (220)Rn by restricting diffusional entry area. Such radon EIC (R EIC) monitors are modified by increasing the entry area to allow (220)Rn, in addition to (222)Rn. Such modified un...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Health physics

دوره 76 6  شماره 

صفحات  -

تاریخ انتشار 1999