Indirect arterial blood pressure measurement in healthy anesthetized cats using a device that combines oscillometry with photoplethysmography

نویسندگان

  • Yasuhiro HEISHIMA
  • Yasutomo HORI
  • Seishiro CHIKAZAWA
  • Kazutaka KANAI
  • Fumio HOSHI
  • Naoyuki ITOH
چکیده

We investigated the basic characteristics of indirect arterial blood pressure (ABP) measurement using a device that combines oscillometry and photoplethysmography in cats. Dobutamine was infused intravenously in four anesthetized cats. Direct ABP was measured by a catheter. Indirect ABP was measured from the left forelimb. Dobutamine significantly elevated both systolic arterial pressure (SAP) and mean arterial pressure (MAP) in a dose-dependent manner. The indirect SAP, MAP and diastolic arterial pressure (DAP) values were closely correlated with the direct ABP values (r=0.88, 0.89 and 0.83, respectively). The mean bias for SAP, MAP and DAP was 3.4, 0.2 and -2.4 mmHg, respectively. The indirect ABP measured by this device may be used to reliably monitor ABP changes in anesthetized cats.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Doppler Ultrasonic and Oscillometric Methods of Indirect Blood Pressure Measurement in Cats

Reliability of 804 indirect measurements of systemic arterial blood pressure (BP) was assessed in 13 cats by comparing results obtained indirectly by oscillometry (BPo) and Doppler ultrasonography (BPud) with those obtained simultaneously by a reference method, direct radiotelemetry (BPrt). The reliability varied considerably among sites of cuff placement and method of indirect measurement in c...

متن کامل

Comparison of high-definition oscillometry -- a non-invasive technology for arterial blood pressure measurement -- with a direct invasive method using radio-telemetry in awake healthy cats.

This study compared indirect blood pressure measurements using a non-invasive method, high-definition oscillometry (HDO), with direct measurements using a radio-telemetry device in awake cats. Paired measurements partitioned to five sub-ranges were collected in six cats using both methods. The results were analysed for assessment of correlation and agreement between the two methods, taking into...

متن کامل

Bilateral photoplethysmography studies of the leg arterial stenosis.

A newly developed portable multi-channel photoplethysmography (PPG) device has been used for comparative studies of 20 healthy control subjects and 45 patients with diagnosed arterial stenosis in a leg. The peripheral blood pulsations were detected simultaneously at four body sites-the same fingers and toes of both arms and legs. The PPG pulses recorded at the periphery of the stenotic leg, if ...

متن کامل

Automatic noninvasive measurement of systolic blood pressure using photoplethysmography

BACKGROUND Automatic measurement of arterial blood pressure is important, but the available commercial automatic blood pressure meters, mostly based on oscillometry, are of low accuracy. METHODS In this study, we present a cuff-based technique for automatic measurement of systolic blood pressure, based on photoplethysmographic signals measured simultaneously in fingers of both hands. After in...

متن کامل

Agreement between direct and indirect blood pressure measurements obtained from anesthetized Hispaniolan Amazon parrots.

OBJECTIVE To determine the level of agreement between direct and indirect blood pressure measurements obtained from healthy Hispaniolan Amazon parrots (Amazona ventralis) anesthetized with isoflurane. DESIGN Validation study. ANIMALS 16 healthy adult Hispaniolan Amazon parrots. PROCEDURES Parrots were anesthetized, and a 26-gauge, 19-mm catheter was placed percutaneously in the superficia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 78  شماره 

صفحات  -

تاریخ انتشار 2016