Pre-clinical validation of a new intra-operative "dual beam Doppler" blood flowmeter in an artificial circuit.

نویسندگان

  • Mustafa Cikirikcioglu
  • Y Banu Cikirikcioglu
  • Ebrahim Khabiri
  • M Karim Djebaili
  • Afksendiyos Kalangos
  • Beat H Walpoth
چکیده

BACKGROUND Intra-operative flow measurement during coronary or peripheral bypass operations is helpful for ruling out technical failures and for prediction of complication and patency rates. Preclinical validation of the flowmeters is required in order to rely on the intra-operatively measured results. The aim of this study is to evaluate a new "dual beam Doppler" blood flowmeter before clinical application and to compare it with the established "transit time flow measure-ment" technique in an artificial circuit. METHODS Measurements were performed in an experimental flow model using pig blood and pig arteries. Three different flowmeters were used: Quantix OR (dual beam doppler flowmeter), CardioMed (transit time flowmeter), and Transonic (transit time flowmeter). Three validation tests were performed to assess correlation, precision, and repeatability of devices. (1) Correlation and agreement analysis was performed with various flow amounts (10-350 mL/min) (n = 160). (2) Device reproducibility and measurement stability were tested with a constant flow (flow amount = 300 mL/min) (n = 30). (3) A user accuracy test (intra- and inter-observer variability) was performed by 5 different observers with a constant flow (flow amount = 205 mL/min) (n = 75). Time collected true flow was used as a reference method in all steps and all tests were performed in a blind manner. Results are shown as mean values +/- standard deviations. Pear-son's correlation and Bland-Altman plot analyses were used to compare measurements. RESULTS The mean flow was 167 +/- 98 mL/min for true flow and 162 +/- 94 mL/min, 165 +/- 94 mL/min, and 166 +/- 100 mL/min for Quantix OR, CardioMed, and Transonic, respectively. Correlation coefficients between Quantix OR, Medi-Stim, Transonic, and time collected true flow were over 0.98 (P = .01). Most of the measured results ( > 90%) were between +/- 1.96 SD agreement limits in Bland and Altman plot analysis. All devices showed good results in the reproducibility test. During the user accuracy test, larger variance changes were observed between intra- and inter-observer results with the dual beam Doppler flowmeter compared to the 2 used transit time flowmeters when used for single sided vessel access without stabilization device (available from the manufacturer). CONCLUSION All 3 tested flowmeters showed an excellent correlation to the true flow in an artificial circuit and the accuracy of the tested devices was within agreement limits. Reproducibility of all devices was good and linear. The new dual beam Doppler flow measurement technique compares favorably to the classic transit time method. Clinical use may depend on operator, location, and condition, thus more studies may be required to ensure uniform results using the currently available blood flow measurement devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

W3: Intra-Operative Imaging and Brain Pathology

The Intraoperative MRI is of great importance in the surgical removal of gliomas or cranial base tumors. However, the sole use of a intraoperative MRI is problematic, so that a dual system has been developed to optimize the utilization of the equipment, which can be used both for neurosurgical patients and for outpatient or stationary Patients. Within the framework of the new head Center at the...

متن کامل

جراحی در بیماران دیابتی

There are more than 140 million people with diabetes in the world. Iran’s share is estimated at 1.5 million people. The increasing prevalence of diabetes and the longer life expectancy of diabetic patients mean that an increasing number of patients with diabetes are undergoing surgery, and not just for diabetes and its complications, such as end-stage renal disease, retinopathy, peripheral vas...

متن کامل

Beam characteristics and leakage assessment of an in-house intra-operative electron applicator system

Background: Intraoperative radiation therapy (IORT) technique is used to treat a surgically exposed tumor or tumor bed in the treatment of locally advanced intraabdominal, retroperitoneal, pelvic, thoracic, breast and soft tissue tumors. One way to perform IORT is to use an existing linac and modify the treatment head using an applicator system. In this study the objectives were to design, and ...

متن کامل

Intra-articular versus Intravenous Tranexamic Acid in Total Knee Arthroplasty: A Randomized Clinical Trial

Background: Total knee arthroplasty (TKA) can cause excessive blood loss requiring allogenic transfusions.Tranexamic acid (TXA) has been increasingly used for lowering blood loss. The present study aimed to comparethe efficacy of intravenous (IV) and intra-articular (IA) administrations of TXA in TKA patients who receive aspirin aschemoprophylaxis and uses no drain post-operat...

متن کامل

Alterations in the vascular β-adrenoceptors of the rabbit knee joint due to acute inflammation

  It has been shown that acute inflammation reduces the effectiveness of sympathetic nerves in the regulation of knee joint blood flow. To investigate the role of vascular β- adrenoceptors in this event, 12 NZW rabbits were maintained anaesthetized by 1 % halothane in N2O/O2, and acute knee joint inflammation was induced by intra-articular injection of 1 ml of 2% carageenan solution 24 hours be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The heart surgery forum

دوره 9 1  شماره 

صفحات  -

تاریخ انتشار 2006