Accuracy of fetal pulse oximetry and pitfalls in measurements.

نویسندگان

  • R Nijland
  • H W Jongsma
  • J G Nijhuis
  • B Oeseburg
چکیده

Pulse oximetry is a technique for estimating arterial oxygen saturation continuously and non-invasively. Reflectance pulse oximetry might become useful for monitoring the fetus during labour but it is much more susceptible to all kinds of physiological variations than the well-established transmission pulse oximetry for neonatal or adult monitoring. This review focuses on the accuracy of reflectance pulse oximetry. Results of human, animal, in vitro and theoretical models indicate that factors such as; blood volume fraction differences, haematocrit, and blood flow differences are major sources for inaccurate pulse oximetry readings in the fetal arterial oxygen saturation range of 10-80%. These factors cannot be overcome by systems using two wavelengths sensors with the 660/890 or 940 nm combination. Reported precision values (S.D. of difference between pulse oximeter and blood sample saturation) range between 2.5 and 12.9% for various 660 nm sensors. Most sensors were tested only once with a limited number of animals. A new 735/890 nm sensor (Nellcor Puritan Bennett) demonstrates a promising accuracy (precision around 5%) in two studies. Various other sensors have also been developed, but are not or scarcely evaluated. Without thorough establishment of the reliability of this technique, clinical fetal oxygen saturation data are still of limited value.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trans-abdominal monitoring of fetal arterial blood oxygenation using pulse oximetry.

Pulse oximetry (oxygen saturation monitoring) has markedly improved medical care in many fields, including anesthesiology, intensive care, and newborn intensive care. In obstetrics, fetal heart rate monitoring remains the standard for intrapartum assessment of fetal well being. Fetal oxygen saturation monitoring is a new technique currently under development. It is potentially superior to elect...

متن کامل

Evaluation and Improvement of Knowledge of Medical staff on Pulse Oximetry in Educational Hospitals

Background: Pulse Oximeter monitoring has become so common over previous decades that in some health care units, blood oxygen level is now considered as the fifth vital sign. However, it seems there is still some lack of knowledge and/or experience among medical staff operating pulse oximeter and interpreting its results. The aim of this study was to investigate and compare the knowledge on Pul...

متن کامل

Evaluation of Pulse Oximetry in the Early Detection of Congenital Heart Diseases in Newborns

Background: Congenital heart diseases, which are asymptomatic at birth, are the most important causes of infant mortality. This study aimed to evaluate the role of pulse oximetry in the early detection of congenital heart diseases among newborns.Methods: In this cross-sectional descriptive study, 1230 newborns who were born in university hospitals in an urban area of Iran were placed unde...

متن کامل

Evaluation and Improvement of Knowledge of Medical staff on Pulse Oximetry in Educational Hospitals

Background: Pulse Oximeter monitoring has become so common over previous decades that in some health care units, blood oxygen level is now considered as the fifth vital sign. However, it seems there is still some lack of knowledge and/or experience among medical staff operating pulse oximeter and interpreting its results. The aim of this study was to investigate and compare the knowledge on Pul...

متن کامل

Notes on the apparent discordance of pulse oximetry and multi-wavelength haemoglobin photometry.

Multi-wavelength photometers, blood gas analysers and pulse oximeters are widely used to measure various oxygen-related quantities. The definitions of these quantities are not always correct. This paper gives insight in the various definitions for oxygen quantities. Furthermore, the possible influences of dyshaemoglobins and fetal haemoglobin on the accuracy of pulse oximetry are discussed. As ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of obstetrics, gynecology, and reproductive biology

دوره 72 Suppl  شماره 

صفحات  -

تاریخ انتشار 1997