Observations of Strong Resistivity Reduction in a Palladium Thin Long Wire Using Ultra—High Frequency Pulsed Electrolysis at D/Pd>1*

نویسندگان

  • F. Celani
  • A. Spallone
  • P. Tripodi
  • D. Di Gioacchino
چکیده

We performed a ultra—short width high voltage pulse electrolysis using a thin Pd wire cathode; a diluted electrolytic solution of D2O+LiOD was used in a peculiar wire—turned electrodes geometry. The deuterated Pd loading was evaluated by the D/Pd normalised electric resistance curve (R/Ro). After a long time of electrolysis a very high D/Pd loading (1:1 or more) was reached. Very low R/Ro (< 0.1) Pd wire was measured after switching off the electrolysis and this effect lasted for several minutes. The Deuterium deloading occurred in several typologies (fast and slow terms) showed as a resistance transition on the Pd wire. This effect can be related to a peculiar surface structural condition. To be published on "Fus.Thec." Presented at the "ICCF-6", Sapporo, Japan, October 13-18, 1996 * Work supported by: INFN, ORIM (Italy); NEDO—NHE (Japan) Palladium wires fabricated by: ORIM

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of Palladium-Alloy Membranes for Hydrogen Separation and Purification

This paper summarizes R&D activities and progress at NORAM Engineering and the University of British Columbia (UBC) on preparation and testing of thin palladium-based membranes and their applications. Most of these activities were carried out internally at NORAM, some jointly with UBC and their spin-off company, Membrane Reactor Technology (MRT) through a wide range of projects. Key results out...

متن کامل

Electrochemical Calorimetric Studies of the Cold Fusion Effect

Several types of calorimetric cell designs were used in attempts to measure excess enthalpy during the electrolysis of LiOD/D2O using palladium cathodes. Control experiments were run by using light water in place of D2O or by using platinum cathodes in place of palladium. Initial experiments using thin palladium cathodes of an unknown purity gave no significant differences between the Pd/D2O ce...

متن کامل

Some problems on the resistance method in the in situ measurement of hydrogen content in palladium electrode

Some problems on the resistance method in determining the hydrogen content in PdHx electrodes are discussed. First, the resistivity ratio of PdHx , the temperature coefficient of resistivity and the resistance of PdHx , and the resistance of Pd having undergone hydriding /dehydriding cycles are discussed. It is found that the resistivity ratio is somewhat higher than the resistance ratio with t...

متن کامل

Improving Gas Sensing Properties of Tin Oxide Nanowires Palladium-Coated Using a Low Cost Technique

Thin films of SnO2 nanowires were successfully prepared by using chemical vapor deposition (CVD) process on quartz substrates. Afterwards, a thin  layer of palladium (Pd) as a catalyst was coated on top of nanowires. For the deposition of Pd, a simple and low cost technique of spray pyrolysis was employed, which caused an intensive enhancement on the sensing response of fabricated sensors...

متن کامل

An Overview of Experimental Studies on H/Pd Over- loading with Thin Pd Wires and Different Electrolytic Solutions

Hundreds of electrolytic loading tests of thin Pd wires in different experimental conditions have been performed in order to find out the best procedures for stable, high hydrogen overloading into the palladium lattice. In a very dilute acid solution thin Pd cathodes (50 or 100m in diameter) and thick Pt anodes (0.5 mm in diameter) were used in a parallel or coaxial geometry. Normalised resist...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002