Insonation method and diagnostic flow signatures for transcranial power motion (M-mode) Doppler.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Power motion mode Doppler (PMD) simultaneously displays flow signal intensity and direction over several centimeters of intracranial space. Insonation protocol for PMD and spectral transcranial Doppler (TCD) with typical PMD flow signatures is described in serial patients with acute stroke symptoms examined via conventional windows with a PMD/TCD unit. RESULTS Thirty-five patients were studied within 12 hours after stroke onset (age 64 +/- 15 years; 8 received intravenous and 3 intra-arterial thrombolysis). One patient had no temporal window, and 3 patients had suboptimal windows. In 90% of patients, PMD showed more than 1 ipsilateral temporal windows. In 63% of patients (n = 22), PMD simultaneously displayed the entire M1 (65-45 mm) and proximal M2 (45-30 mm) flows, leading to spectral TCD examination of the proximal M2 middle cerebral artery (MCA) in 28 of 35 patients (80%). All patients had sufficient foraminal (depth display = 60-110 mm) and orbital (depth display = 30-80 mm) windows. PMD displayed the entire basilar artery stem (75-100+ mm) in 69% (n = 24) of patients, and the distal basilar flow was detected in all patients by both PMD and TCD. TCD results were normal (12), proximal intracranial stenosis (5), large vessel occlusion (17), and cerebral circulatory arrest (1). Compared to spectral TCD, PMD signatures of similar diagnostic significance were low resistance (vessel identification and recanalization), high resistance (ophthalmic artery identification and distal obstruction), collateral (communicating arteries and leptomeningeal flow), reverberating (circulatory arrest), and branch embolization. CONCLUSIONS PMD is a window-finding tool and a guide for spectral TCD gate placement. PMD facilitates flow detection in the M2 branches and the distal basilar artery. PMD can demonstrate recanalization of the entire MCA main stem and proximal branches, increase the yield of embolus detection and procedure monitoring, and facilitate abnormal flow pattern recognition.
منابع مشابه
Applications and advantages of power motion-mode Doppler in acute posterior circulation cerebral ischemia.
BACKGROUND AND PURPOSE Evaluation of posterior circulation with single-gate transcranial Doppler (TCD) is technically challenging and yields lower accuracy parameters in comparison to anterior circulation vessels. Transcranial power motion-mode Doppler (PMD-TCD), in addition to spectral information, simultaneously displays in real-time flow signal intensity and direction over 6 cm of intracrani...
متن کاملI-47: Doppler Ultrasound Diagnosis of Intrauterine Lesions
Background In patients with abnormal uterine bleeding, transvaginal ultrasound (TVS) is the first-line diagnostic approach to exclude endometrial pathology. If a thickened endometrium suggests endometrial pathology, sonohysterography, office hysteroscopy or dilatation and curettage are the second-line tests preferred, depending on availability and on the suspected pathology, to exclude malignan...
متن کاملDiagnostic criteria and yield of real-time transcranial Doppler monitoring of intra-arterial reperfusion procedures.
BACKGROUND AND PURPOSE Intra-arterial (IA) rescue procedures are increasingly used to treat acute ischemic stroke. We implemented continuous transcranial Doppler (TCD) monitoring during these procedures to detect any potentially harmful flow changes. Here, we report diagnostic criteria and yield of TCD monitoring. METHODS We studied consecutive acute stroke patients who underwent IA reperfusi...
متن کاملTranscranial Doppler ultrasonography in the assessment of cerebral circulation arrest: improving sensitivity by transcervical and transorbital carotid insonation and serial examinations.
INTRODUCTION Transcranial Doppler (TCD) can detect the cerebral circulation arrest (CCA) in brain death. TCD is highly specific, but less sensitive because of false-negatives accounting for up to 10%. The aim of the study was to explore the diagnostic accuracy of TCD and to determine whether it can be augmented by strategies such as the insonation of the extracranial internal carotid artery (IC...
متن کاملFrontal bone windows for transcranial color-coded duplex sonography.
BACKGROUND AND PURPOSE The use of the conventional temporal bone window for transcranial color-coded duplex sonography (TCCS) often results in difficulties in obtaining angle-corrected flow velocity measurements of the A2 segment of the anterior cerebral artery, the posterior communicating artery, and the midline venous vasculature because of the unfavorable insonation angle. The same applies t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of neuroimaging : official journal of the American Society of Neuroimaging
دوره 12 3 شماره
صفحات -
تاریخ انتشار 2002