An analysis of the regulatory program of quality audits in radiotherapy in Brazil from 1995 to 2007

نویسندگان

  • Eduardo de Paiva
  • Luiz A. R. da Rosa
  • Ricardo R. A. Brito
  • Lidia V. de Sá
  • Ana C. M. Dovales
  • Delano V. S. Batista
  • Ricardo A. Giannoni
  • Alexandre F. Velasco
چکیده

The Brazilian Institute of Radiation Protection and Dosimetry (IRD/CNEN) carried out quality assurance regulatory audits in Brazilian radiotherapy facilities from 1995 to 2007. In this work, the set of data collected from 195 radiotherapy facilities that use high-energy photon beams are analyzed. They include results from audits in linear electron accelerators and/or Co-60 units. The inspectors of IRD/CNEN performed the dosimetry of high-energy radiotherapy photon beams according to the IAEA dosimetry protocols TRS 277 and TRS 398, and the values of measurements were compared to stated values. Other aspects of radiological protection were checked during on-site audits such as calibration certification of clinical dosimeters and portable monitors, existence and use of check source, use of barometer and thermometer, individual dose registry and training of staff. It was verified that no check source was available in 38% of the visited facilities; the training of personnel was not adequate in 9% of the facilities and the registry of accumulated individual doses was not being done in 6% of the facilities. Measurements of absorbed dose have indicated deviations in the range ± 3% for 67.6% of the cobalt-60 units and 79.6% of medical linear accelerators; 18.5% of Co-60 irradiators and 9.6% of linear accelerators presented deviations in the range 3% < δ ≤ 5%. Finally, 13.9% of Co-60 facilities and 10.8% of linear accelerator facilities presented dosimetry deviations above 5%. The effort in dosimetric quality control performed by IRD/CNEN audits has yielded positive changes that make radiation treatment facilities more reliable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Photon Dosimetry Quality Audit of Radiotherapy Centers in Iran: SSDL's On-Site Visit Program During 2007-2017

Introduction: A dosimetric audit is a quality assurance process (QA) that allows the accuracy of dosimetric and geometric precision to accurately control the delivery of doses. They can be used to evaluate the accuracy of radiation delivery at different radiotherapy centers. Differences in prescriptive doses, depending on the severity of the differences, have potential conseque...

متن کامل

Sunflower Meal and Enzyme Supplementation in Diets of Broilers from 21 to 42 Days of Age

The objective of this study was to evaluate the performance of male broiler chickens in the period from 21 to 42 days of age fed diets with increasing levels of sunflower meal (SM) supplemented with an enzyme complex (EC). A total of 1920 animals of the Cobb strain were distributed in a randomized block design in a 4 × 3 factorial arrangement (four SM levels and three enzymes utilization types)...

متن کامل

DNA damage in dental pulp mesenchymal stem cells: An in vitro study

The aim of this study was to evaluate the potential use of a DNA comet assay, DNA fragmentation fluorimetric assay and reactive oxygen species levels as potential biomarkers of genome conditions of dental pulp stem cells (DPSCs) isolated from dog canine teeth. Mesenchymal stem cells were isolated from the dental pulp collected from dog teeth. The results obtained suggest the ideal moment for cl...

متن کامل

Impact of floating platforms on the limnological aspects of hydropower plant reservoirs

Floating platforms at the hydropower plant reservoirs are attractive sites for aquaculture, fishing and other recreational activities. However, the unregulated construction of these platforms may negatively affect the fauna, flora and water quality of reservoirs. Thus, this study aimed to evaluate the impact of floating platforms on the limnological aspects of Nova Ponte hydropower plant reserv...

متن کامل

Auditor Type and Earnings Quality in Tehran Stock Exchange

This study examines the association between auditor type (public versus private) and earnings quality as measured by the levels of discretionary accruals in Iran. This study hypothesize that there is no significant difference in discretionary accruals between public and private sector audit firms when there is low incentives for auditors to provide high-quality audits in Iran. Using a sample...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2011