Circulating current analysis between strands in armature winding of a turbo-generator using analytical model
نویسندگان
چکیده
In this paper, the circulating current analysis between strands is studied while considering the different transpositions in the active part and without considering the transposition in the end winding region. First, this analysis is done while only considering the slot region, and then the end winding region is added to the model. The model used for this analysis is a circuit model, including the resistance and inductance of the strands and their induced backelectromotive force (EMF). The back-EMF sources and inductances are calculated through a 2D finite element analysis (FEA) of the active part and a 3D FEA for the end winding region. For the slot region analysis, the results show that the 360◦ and 540◦ transpositions are the best. Moreover, when considering the end winding region in analysis, the results obtained show that the 540◦ transposition minimizes the circulating current more than any other transposition. Finally, for different transpositions, the obtained results are compared among themselves and with the results of the untransposed model.
منابع مشابه
Synchronous Generator Model Identification and Parameter Estimation From Operating Data
A novel technique to estimate and model parameters of a 460-MVA large steam turbine generator from operating data is presented. First, data from small excitation disturbances are used to estimate linear model armature circuit and field winding parameters of the machine. Subsequently, for each set of steady state operating data, saturable inductances and are identified and modeled using nonlinea...
متن کاملDevelopment of an Analytic Model for Flux Switching Motors
This paper presents developing an analytical model for flux switching motors. The motor is a class of variable reluctance motors that has two windings on stator; a field winding and an armature winding. Due to saliency of both stator and rotor poles, accurate modeling is difficult which arises from the nonlinear behavior of the machine. This paper presents a simple model which is able to predic...
متن کاملInfluence of Rectifiers on Permanent Magnet Wind Generator Electromagnetic and Temperature Fields
Abstract: Power rectifiers are very necessary in the wind power generation systems since they are the necessary channels that link the generator and power gird together. However, they have some effects on the permanent magnet wind generator due to their work on fast on-off transitions. Taking an 8kW 2000r/min wind-driven permanent magnet generator as an example, the system model and external ci...
متن کاملCharacterization of Power Transformer Electromagnetic Forces Affected by Winding Faults
Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...
متن کاملAnalysis of Magnetic Flux Linkage Distribution in Salient-Pole Synchronous Generator with Different Kinds of Inter-Turn Winding Faults
A reliable and accurate diagnosis of inter-turn short circuit faults is a challenging problem in the area of fault diagnosis of electrical machines. The purpose of this challenge is to be more efficient in fault detection and to provide a reliable method with low-cost sensors and simple numerical algorithms which not only detect the occurrence of the fault, but also locate its position in the w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -