Optimizing the diagnostic power with gastric emptying scintigraphy at multiple time points

نویسندگان

  • Qingjiang Hou
  • Zhiyue Lin
  • Reginald Dusing
  • Byron J Gajewski
  • Richard W McCallum
  • Matthew S Mayo
چکیده

BACKGROUND Gastric Emptying Scintigraphy (GES) at intervals over 4 hours after a standardized radio-labeled meal is commonly regarded as the gold standard for diagnosing gastroparesis. The objectives of this study were: 1) to investigate the best time point and the best combination of multiple time points for diagnosing gastroparesis with repeated GES measures, and 2) to contrast and cross-validate Fisher's Linear Discriminant Analysis (LDA), a rank based Distribution Free (DF) approach, and the Classification And Regression Tree (CART) model. METHODS A total of 320 patients with GES measures at 1, 2, 3, and 4 hour (h) after a standard meal using a standardized method were retrospectively collected. Area under the Receiver Operating Characteristic (ROC) curve and the rate of false classification through jackknife cross-validation were used for model comparison. RESULTS Due to strong correlation and an abnormality in data distribution, no substantial improvement in diagnostic power was found with the best linear combination by LDA approach even with data transformation. With DF method, the linear combination of 4-h and 3-h increased the Area Under the Curve (AUC) and decreased the number of false classifications (0.87; 15.0%) over individual time points (0.83, 0.82; 15.6%, 25.3%, for 4-h and 3-h, respectively) at a higher sensitivity level (sensitivity=0.9). The CART model using 4 hourly GES measurements along with patient's age was the most accurate diagnostic tool (AUC=0.88, false classification=13.8%). Patients having a 4-h gastric retention value>10% were 5 times more likely to have gastroparesis (179/207=86.5%) than those with ≤10% (18/113=15.9%). CONCLUSIONS With a mixed group of patients either referred with suspected gastroparesis or investigated for other reasons, the CART model is more robust than the LDA and DF approaches, capable of accommodating covariate effects and can be generalized for cross institutional applications, but could be unstable if sample size is limited.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of gastric-emptying scintigraphy of solids and liquids in mice using dedicated animal pinhole scintigraphy.

UNLABELLED Gastric emptying in small laboratory animals is a useful parameter to assess gastrointestinal motility for physiologic, pharmacologic, or other research purposes. In mice, phenol red recovery is considered the gold standard for determination of gastric emptying. However, this method requires sacrifice of the animal and yields data of gastric emptying at only 1 time point. Gastric-emp...

متن کامل

Scintigraphic evaluation of gastric emptying after greater curvature plication in comparison with sleeve gastrectomy

Introduction: Laparoscopic gastric plication (LGP) is a relatively new restrictive bariatric procedure that emerged to avoid the problems and to reduce the cost of laparoscopic sleeve gastrectomy. In this study we present the initial short-term outcome of LGP and its effect on gastric emptying and compare it with the results of laparoscopic sleeve gastrectomy (LSG). <stro...

متن کامل

Scintigraphic evaluation of abomasal emptying rate in neonatal suckling lambs

Evaluation of gastric emptying rate using nuclear scintigraphy as the gold standard method has been studied in various animals, but there is no report in suckling lambs. The aim of this study was to develop a nuclear scintigraphic method to visualize and measure abomasal emptying rate by estimation of scintigraphic half emptying time (T1/2) in the live neonatal lamb. Five healthy, female Irania...

متن کامل

Assessment of the Prevalence of Diabetic Gastroparesis and Validation of Gastric Emptying Scintigraphy for Diagnosis

OBJECTIVE Gastroparesis is defined as delayed gastric emptying and is a common medical condition in diabetic patients. Scintigraphy is commonly used as a standard diagnostic procedure for the quantitative assessment of gastroparesis. The aims of this study were to determine an optimum imaging time for the diagnosis of gastroparesis, to assess the prevalence of gastroparesis, to evaluate the cor...

متن کامل

Comparison of gastric emptying of a nondigestible capsule to a radio-labelled meal in healthy and gastroparetic subjects.

BACKGROUND Gastric emptying scintigraphy (GES) using a radio-labelled meal is used to measure gastric emptying. A nondigestible capsule, SmartPill, records luminal pH, temperature, and pressure during gastrointestinal transit providing a measure of gastric emptying time (GET). AIMS To compare gastric emptying time and GES by assessing their correlation, and to compare GET and GES for discrimi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2011