Preconcentration and determination of trace metals in seawater using a thiol cotton fiber minicolumn coupled with inductively coupled plasma mass spectrometry.

نویسندگان

  • Shuzhen Zhang
  • Anxiang Lu
  • Fang Han
  • Xiao-quan Shan
چکیده

A rapid separation and preconcentration method was developed for the determination of trace metals Cu, Zn, Cd, and Pb in seawater using a minicolumn packed with thiol cotton fiber (TCF) coupled with inductively coupled plasma mass spectrometry (ICP-MS). Preconcentration parameters, such as seawater sample volume and flow rate and eluent hydrochloric acid concentration, volume and flow rate, were optimized. Under the optimized conditions, trace metals Cu, Zn, Cd, and Pb in seawater can be determined with no interference from saline matrices. When a sample volume of 1500 ml and a sample flow rate of 15 ml min(-1) were used, the preconcentration factor of 1500 and RSD value of <7% at ng ml(-1) were achieved. The accuracy of the recommended method was verified by the analysis of certified reference materials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Selective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry

In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...

متن کامل

Sample pretreatment using chitosan-based chelating resin for the determination of trace metals in seawater samples by inductively coupled plasma-mass spectrometry.

A sample-pretreatment method using a chitosan-based chelating resin, ethylenediamine-N,N,N'-triacetate-type chitosan (EDTriA-type chitosan), was developed for the preconcentration of trace metals in seawater and separation of the seawater matrix prior to their determination by inductively coupled plasma-mass spectrometry (ICP-MS). The resin showed very good adsorption for transition metals and ...

متن کامل

Preconcentration of ultratrace rare earth elements in seawater with 8-hydroxyquinoline immobilized polyacrylonitrile hollow fiber membrane for determination by inductively coupled plasma mass spectrometry

8-Hydroxyquinoline immobilized on polyacrylonitrile hollow fiber membrane was synthesized and used for the preconcentration of rare earth elements (REEs) and the separation of the matrix in seawater prior to their determination by inductively coupled plasma mass spectrometry (ICP-MS). Both the capacity and chemical stability of the modified polyacrylonitrile hollow fiber membrane have been eval...

متن کامل

Multiple-element detection in aqueous solution and seawater by using an on-line preconcentration method for inductively coupled plasma mass spectrometry.

Inductively coupled plasma-mass spectrometry (ICP-MS) incorporated with an on-line preconcentration system was used to determine trace amounts of ten metals including Ni, Cu, Zn, Rh, Ag, Cd, In, Au, Tl, and Pb in aqueous solutions and seawater. These metals, which formed the complexes, were retained in a sorbent microcolumn, followed by elution with methanol through a desolvation unit, which wa...

متن کامل

On-line preconcentration with a novel alkyl phosphinic acid extraction resin coupled with inductively coupled plasma mass spectrometry for determination of trace rare earth elements in seawater.

A newly synthesized alkyl phosphinic acid resin (APAR) was used for on-line preconcentration of trace rare earth elements (REES, lanthanides including yttrium) and then determined by inductively coupled plasma mass spectrometry. REEs in seawater could be on-line concentrated on the APAR packed column (4.6mm i.d.x50mm in length), and eluted from the column with 0.5mL 0.1molL(-1) nitric acid with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 21 6  شماره 

صفحات  -

تاریخ انتشار 2005