Computer-automated tinnitus assessment: noise-band matching, maskability, and residual inhibition.

نویسندگان

  • James A Henry
  • Larry E Roberts
  • Roger M Ellingson
  • Emily J Thielman
چکیده

BACKGROUND Psychoacoustic measures of tinnitus typically include loudness and pitch match, minimum masking level (MML), and residual inhibition (RI). We previously developed and documented a computer-automated tinnitus evaluation system (TES) capable of subject-guided loudness and pitch matching. The TES was further developed to conduct computer-aided, subject-guided testing for noise-band matching (NBM), MML, and RI. PURPOSE The purpose of the present study was to document the capability of the upgraded TES to obtain measures of NBM, MML, and RI, and to determine the test-retest reliability of the responses obtained. RESEARCH DESIGN Three subject-guided, computer-automated testing protocols were developed to conduct NBM. For MML and RI testing, a 2-12 kHz band of noise was used. All testing was repeated during a second session. STUDY SAMPLE Subjects meeting study criteria were selected from those who had previously been tested for loudness and pitch matching in our laboratory. A total of 21 subjects completed testing, including seven females and 14 males. RESULTS The upgraded TES was found to be fairly time efficient. Subjects were generally reliable, both within and between sessions, with respect to the type of stimulus they chose as the best match to their tinnitus. Matching to bandwidth was more variable between measurements, with greater consistency seen for subjects reporting tonal tinnitus or wide-band noisy tinnitus than intermediate types. Between-session repeated MMLs were within 10 dB of each other for all but three of the subjects. Subjects who experienced RI during Session 1 tended to be those who experienced it during Session 2. CONCLUSIONS This study may represent the first time that NBM, MML, and RI audiometric testing results have been obtained entirely through a self-contained, computer-automated system designed specifically for use in the clinic. Future plans include refinements to achieve greater testing efficiency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Residual inhibition functions in relation to tinnitus spectra and auditory threshold shift.

CONCLUSIONS Psychoacoustic functions relating the depth and duration of tinnitus suppression ('residual inhibition') to the center frequency of band-passed noise masking sounds appear to span the region of hearing loss, as do psychoacoustic measurements of the tinnitus spectrum. The results (1) suggest that cortical map reorganization induced by hearing loss is not the principal source of the t...

متن کامل

Characterisitics and maskability of self-reported tinnitus in adult Nigerians.

BACKGROUND Tinnitus or noise perception with no identifiable acoustic origin is a perplexing symptom to sufferers as well as to otolaryngologists saddled with managing such patients. With most studies from the continent focusing on etiologies and clinical types, there is paucity of information on psychoacoustic properties of tinnitus among Africans. SETTING Tertiary care otolaryngology clinic...

متن کامل

Psychoacoustic measures of tinnitus.

This report reviews research from the 1930s to the present that has extended our understanding by investigating the characteristics of tinnitus that can be studied using psychoacoustic techniques. Studies of tinnitus masking and residual inhibition began in the 1970s, leading to the therapeutic use of tinnitus masking and a consequent increase in research devoted to tinnitus measurement. In 198...

متن کامل

Design of an S-band Ultra-low-noise Amplifier with Frequency Band Switching Capability

In this paper, an ultra-low-noise amplifier with frequency band switching capability is designed, simulated and fabricated. The two frequency ranges of this amplifier consist of the 2.4 to 2.5 GHz and 3.1 GHz to 3.15 GHz frequency bands. The designed amplifier has a noise figure of less than 1dB, a minimum gain of 23 dB and a VSWR of less than 2 in the whole frequency band. The design process s...

متن کامل

Longitudinal follow-up of tinnitus complaints.

OBJECTIVE To investigate the long-term outcome of patients with tinnitus, the long-term effects of cognitive behavioral therapy, and what properties of tinnitus predict distress at follow-up. DESIGN A longitudinal follow-up of a consecutive sample of patients with tinnitus initially seen by a clinical psychologist. SETTING Department of Audiology, University Hospital, Uppsala, Sweden. PAR...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Academy of Audiology

دوره 24 6  شماره 

صفحات  -

تاریخ انتشار 2013