Influence of matrix on concentrations of somatotropin measured in serum with commercial immunoradiometric assays.
نویسندگان
چکیده
Using immunoradiometric assays (IRMAs) from Hybritech Inc. (H) and Nichols Institute Diagnostics (ND), we measured somatotropin (human growth hormone, hGH) in serum samples obtained every 20 min for 24 h from 10 prepubertal subjects with short stature. Results obtained with the ND reagents were 2.74 times greater than those obtained with the H reagents (P = 0.00001, r = 0.94, SEE = 3.9, n = 720). We therefore compared the IRMAs with the standard hGH RIA from the National Institutes of Health (NIH) National Hormone and Pituitary Program, using the genetically engineered hGH preparations (from Genentech Inc.) 22-kDa hGH and methionated 20-kDa hGH. We also assayed human pituitary hGH (NIH, lot no. AFP-4793B). Each hGH preparation was diluted in three diluent buffer systems: horse serum from H and from ND, and human serum. The RIA and H-IRMA gave superimposable standard curves for all hGH preparations in each diluent. The methionated 20-kDa hGH was not detected in the H-assay. Use of human serum matrix in the ND-IRMA shifted the standard curve as compared with the horse-serum matrix, giving equivalent binding at lower concentrations; i.e., serum hGH was overestimated in samples assayed against standards diluted in horse serum. Quality-control materials (Ciba-Corning) yielded disparate results in all three assays, yet human serum pools containing hGH gave similar results in the H and the NIH assays, and higher values in ND. When a human serum standard was used in the ND assay, both IRMAs gave similar results to the RIA assay for human serum samples. Reference intervals for hGH should be determined by each analytical laboratory, to prevent misdiagnosis of patients. Furthermore, quality-control material should be of human origin, because commercially supplied quality-control material does not react the same as human serum in some hGH assays.
منابع مشابه
Preparation of prostate specific antigen standards for immunoradiometric assay
Background: Immunoradiometric assay is one of the most common and precise methods for determination of prostate specific antigen (PSA) in clinical laboratories. Usual use of human serum in routine assays has many disadvantages such as easy contamination and precipitation, instability and unavailability. Thus in order to avoid these problems the artificial matrix was used which acts sim...
متن کاملCross-reactivity of monomeric and dimeric biosynthetic human growth hormone in commercial immunoassays.
Commercial kits give different measurements for concentrations of growth hormone (GH, somatotropin) in serum. Most notably, a two-site monoclonal-antibody-based immunoradiometric assay (IRMA) from Hybritech routinely yields lower values than do conventional RIAs in which polyclonal antibodies are used. We used purified dimeric biosynthetic human GH as a model compound to investigate the specifi...
متن کاملThree commercial methods for serum ferritin compared and the high-dose "hook effect" eliminated.
We evaluated four commercial kits for measuring serum ferritin, based on three techniques: immunoradiometric assay, radioimmunoassay, and enzyme immunoassay. The kits evaluated were those manufactured by Abbott Laboratories, Clinical Assays, Corning Medical, and Ramco. Two of the immunoradiometric kits showed satisfactory results with respect to sensitivity and precision; they should be useful ...
متن کاملPreparation of prostate specific antigen standards for immunoradiometric assay
Prostate cancer is the sixth most common cancer in the world, the third most common cancer in men. In 2000, the number of new cases of prostate cancer was estimated at 513000 worldwide and this disease accounts for 9.7% of all cancers in men (1, 2). Thus early detection and local treatment have been advocated in an effort to influence the significant morbidity and mortality associated with the ...
متن کاملUrinary growth hormone excretion as a screening test for growth hormone deficiency.
Overnight urinary growth hormone secretion was measured by an immunoradiometric assay incorporating commercially available reagents, in 41 normal prepubertal school-children from three age groups: 3-5 years, 6-7 years, and 9-10 years. There was no significant difference between the groups expressing the results as total microU/specimen and so they have been combined to provide a prepubertal ref...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 35 7 شماره
صفحات -
تاریخ انتشار 1989