Interaction of beta-amyloid(1-40) peptide with pairs of metal ions: An electrospray ion trap mass spectrometric model study.
نویسندگان
چکیده
The stoichiometries and the affinity toward simple and paired metal ions of synthetic amyloid-beta(1-40) peptide (Abeta1-40) were investigated by electrospray ion trap mass spectrometry (ESI-MS), circular dichroism (CD), and atomic force microscopy (AFM). The results lead to the working hypothesis that pH-dependent metal binding to Abeta1-40 may induce conformational changes, which affect the affinity toward other metals. A significant copper and zinc binding to Abeta1-40 peptide at pH 5.5 was found, whereas nickel ions commonly bind to each molecule of beta-amyloid peptide. Some complexes of Abeta1-40 with more than one nickel ion were identified by ESI-MS. In addition, nickel ions proved to enhance Abeta oligomerization. On increasing pH, up to 12 ions of zinc may bind to a single Abeta molecule. Under the same pH and concentration conditions, the binding pattern of the independent copper and silver ions to Abeta1-40 was different from that of the equimolecular mixture of the two metal ions. One might assume that some conformational changes due to water loss altered the capacity of Abeta peptide to bind certain heavy metal ions. As a consequence, copper-silver interaction with the binding process to Abeta1-40 became highly complex. A competition between silver and nickel ions for Abeta1-40 binding sites at high pH was also observed. New strategies were proposed to identify the characteristic signals for some important metal ion-peptide complexes in the spectra recorded at high pH or high concentrations of metal ions. To explain the formation of such a large number of high metal ion-Abeta complexes, we took into consideration the participation of both histidine residues and free amino groups as well as carboxylate ones in the binding process. Finally, CD and AFM studies supported the mass spectrometric data.
منابع مشابه
A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملQuantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)
The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...
متن کاملA Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملSelf-pairing of 1-methylthymine mediated by two and three Ag(I) ions: a gas phase study using infrared dissociation spectroscopy and density functional theory.
Metal base pairs of Ag(I) cations and 1-methylthymine (1MT) or deprotonated 1-methylthymine (1MT-H) are produced and analyzed by electrospray ionization mass spectrometry (ESI-MS). Mass-selected ions of type [Ag2(1MT)(1MT-H)](+) and [Ag3(1MT-H)2](+) are interrogated by infrared multiple-photon dissociation (IRMPD) in an ion trap in the range of 1200-3700 cm(-1). Supporting spectroscopic data we...
متن کاملAdvantages of Orthogonal Nebulizer Orientation in Electrospray for Quadrupole and Ion Trap Mass Spectrometers
With the increasing popularity of atmospheric pressure ionization (API) mass spectrometric techniques, electrospray ionization has become a widespread tool for quantitative determinations. When the sample matrix is complex, electrospray ionization can result in the formation of nondesolvated, charged residues as well as analyte ions (see Figure 1). These nondesolvated residues contaminate the i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biophysical chemistry
دوره 144 1-2 شماره
صفحات -
تاریخ انتشار 2009