Characterization of the BOLD Hemodynamic Response Function at 7T: towards separation of vasculature and parenchyma
نویسندگان
چکیده
Introduction A limitation of T2weighted BOLD fMRI is the confounding contribution of signal from the larger vasculature. An improved BOLD specificity to parenchyma can be achieved at high field strengths such as 7T due to increased contrast-to-noise ratio, and reduced contribution of intravascular signal as compared to lower field strengths. Moreover, at 7T high spatial and temporal resolution of the BOLD signal can be achieved [1], making it possible to investigate the BOLD response in much finer detail. Previous human work at 3T has shown that the temporal characteristics of the BOLD response in the visual cortex are related to the organization of the local vasculature [2]. A correlation of the time-to-peak (TTP) and width (FWHM) of the BOLD response function was shown. Based on this previous work we expect to obtain a better separation between parenchyma and the macrovasculature at a high resolution. We characterized the spatio-temporal properties of the BOLD response in the visual cortex at 7T using an event-related fMRI paradigm with very short visual stimuli, higher sampling rate, and for different spatial resolutions.
منابع مشابه
Spin Echo Hemodynamic Impulse Response at 7 T
Introduction Understanding the mechanism of neurovascular coupling underlying the BOLD fMRI signal is contingent on the accurate spatial and temporal characterization of the hemodynamic impulse response (HIR), linked specifically to the microvasculature (capillary bed). At high field strength (≥7T), the gradient-echo (GE) HIR can differ across cortical depth [1,2], suggesting that voxels deeper...
متن کاملNon-Linearities of the BOLD Response in the Human Brain
In this study, event-related functional magnetic resonance imaging (fMRI) studies were performed on healthy volunteers at 7 Tesla (T), the highest field strength currently available for human studies. This study assessed the linearity of the hemodynamic response to short-duration stimuli of 0.25s, 0.5s, 1.0s, and 2.0s. This study expected clearer resolution at 7T. Results showed that the hemody...
متن کاملThe relationship between 7T fMRI BOLD and MEG derived γ activity
Introduction: The move to high field imaging is thought to be very beneficial for fMRI, promising an improved signal to noise ratio and increased BOLD contrast alongside increased spatial specificity [1]. It has been shown that the field strength dependence of the fractional signal change varies depending on the relative contributions of capillary and non-capillary venous vessels, with an incre...
متن کاملPathological and Doppler Ultrasonographic Study of Kidney Hemodynamic Response in Saffron (Crocus Sativua) Pretreated Rats
Objective- To evaluate kidney hemodynamic response including blood flow velocity in segmental arteries shortly after administration of various dose of saffron extract (10, 40 and 90 mg/kg). Design- Technical assessment, experimental study. Animals- 20 healthy male Sprague-Dawley rats. Procedures- In this study, using a real-time pulsed doppler analysis, kidney hemodynamic response inc...
متن کاملHemodynamic response changes in cerebrovascular disease: implications for functional MR imaging.
BACKGROUND AND PURPOSE Patients with cerebrovascular occlusive disease may develop compensatory changes in local cerebral vasculature with a resultant loss of vascular reactivity. These alterations can affect the blood oxygen level-dependent (BOLD) signal that is the basis for functional MR imaging. We investigated the BOLD signal in patients with unilateral cerebrovascular disease to ascertain...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009