Treatment Machines for External Beam Radiotherapy
نویسنده
چکیده
Since the inception of radiotherapy soon after the discovery of X rays by Roentgen in 1895, the technology of X ray production has first been aimed towards ever higher photon and electron beam energies and intensities, and more recently towards computerization and intensity modulated beam delivery. During the first 50 years of radiotherapy the technological progress was relatively slow and mainly based on X ray tubes, van de Graaff generators and betatrons. The invention of the 60 Co teletherapy unit by H.E. Johns in Canada in the early 1950s provided a tremendous boost in the quest for higher photon energies and placed the cobalt unit at the forefront of radiotherapy for a number of years. The concurrently developed medical linacs, however, soon eclipsed cobalt units, moved through five increasingly sophisticated generations and became the most widely used radiation source in modern radiotherapy. With its compact and efficient design, the linac offers excellent versatility for use in radiotherapy through isocentric mounting and provides either electron or megavoltage X ray therapy with a wide range of energies. In addition to linacs, electron and X ray radiotherapy is also carried out with other types of accelerator, such as betatrons and microtrons. More exotic particles, such as protons, neutrons, heavy ions and negative p mesons, all produced by special accelerators, are also sometimes used for radiotherapy; however, most contemporary radiotherapy is carried out with linacs or teletherapy cobalt units.
منابع مشابه
Out-Of-Field Dose Measurement and Second Cancer-Risk Estimation Following External Beam Radiotherapy and Brachytherapy for Cervical Cancer Treatment: A Phantom Study
Introduction: The present study aimed to measure the scatter and leakage dose received by out-of-field organs while delivering Radiotherapy (RT) treatment of cervical cancer. Moreover, this study estimated the risk of second cancer (SC). The doses to out-of-field organs were measured using a lithium fluoride (TLD 100) dosimeter while delivering External Beam Radiothera...
متن کاملCalculation and Comparison of Heart Integral Dose in The Treatment of Esophagus Cancer with Three Photon Energies & Using CT Simulation and Treatment Planning System
Introduction: Esophageal cancer is one of the most frequently occurring cancers in Iran and having a high incidence rate among other countries. Radiotherapy is one of the three methods (surgery, radiotherapy and chemotherapy) for radical or palliative treatment of esophageal cancer. In this method of treatment, the organs such as heart and spinal cord are regarded as organs at r...
متن کاملDosimetric Characteristics of Transparent Bolus for External Beam Radiotherapy
Introduction: In radiotherapy, the bolus is often used while treating the tumor under the uneven surfaces of the patients for correcting the anatomical irregularities and increasing skin dose. Wet cotton and wet gauze are still used in developing countries, since the use of wet cotton and wet gauze has certain disadvantages, there is a need for transparent bolus which ...
متن کاملOptimization of Beam Orientation and Weight in Radiotherapy Treatment Planning using a Genetic Algorithm
Introduction: The selection of suitable beam angles and weights in external-beam radiotherapy is at present generally based upon the experience of the planner. Therefore, automated selection of beam angles and weights in forward-planned radiotherapy will be beneficial. Material and Methods: In this work, an efficient method is presented within the MATLAB environment to investigate how to improv...
متن کاملمقایسه روش پرتو درمانی هدفمند با به کارگیری دیاکسی یوریدین نشان دار شده با ید ـ 125 با روش پرتو درمانی خارجی، در درمان گلیوما در شرایط
Gliomas comprise about 50% of all primary central nervous system tumors that have defied treatment. Despite of improvement in treatment with surgery, radiotherapy and chemotherapy, the prognosis for these patients remains poor. Efforts to improve the treatment of malignant glioma have included Targeted Radiotherapy with [125I]-Iododeoxyuridine. 125IUdR, a thymidine analogue, is preferen...
متن کاملEvaluation of Accuracy and Quality assurance of external beam therapy with photons
Introduction: Receiving exact dose by the patients is vital in radiotherapy. In radiation therapy, the dosimetry of radiations is too important because of successful radiation inquires for delivering the exact dose to the target volume. This study is to evaluate the tolerances and the accuracy of calculated dose of photon beams in the treatment software system. The TECDOC1583 p...
متن کامل